Export limit exceeded: 22272 CVEs match your query. Please refine your search to export 10,000 CVEs or fewer.
Search
Search Results (22272 CVEs found)
| CVE | Vendors | Products | Updated | CVSS v3.1 |
|---|---|---|---|---|
| CVE-2025-53818 | 2026-04-15 | N/A | ||
| GitHub Kanban MCP Server is a Model Context Protocol (MCP) server for managing GitHub issues in Kanban board format and streamlining LLM task management. Version 0.3.0 of the MCP Server is written in a way that is vulnerable to command injection vulnerability attacks as part of some of its MCP Server tool definition and implementation. The MCP Server exposes the tool `add_comment` which relies on Node.js child process API `exec` to execute the GitHub (`gh`) command, is an unsafe and vulnerable API if concatenated with untrusted user input. As of time of publication, no known patches are available. | ||||
| CVE-2025-53100 | 2026-04-15 | N/A | ||
| RestDB's Codehooks.io MCP Server is an MCP server on the Codehooks.io platform. Prior to version 0.2.2, the MCP server is written in a way that is vulnerable to command injection attacks as part of some of its MCP Server tools definition and implementation. This could result in a user initiated remote command injection attack on a running MCP Server. This issue has been patched in version 0.2.2. | ||||
| CVE-2024-43653 | 2026-04-15 | 8.8 High | ||
| Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root This issue affects Iocharger firmware for AC model chargers before version 24120701. Likelihood: Moderate – The <redacted> binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a crafted HTTP request. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y). | ||||
| CVE-2024-43654 | 2026-04-15 | 8.8 High | ||
| Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability in Iocharger firmware for AC models allows OS Command Injection as root This issue affects all Iocharger AC EV charger models on a firmware version before 25010801. Likelihood: Moderate – The <redacted> binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a crafted HTTP request. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y). | ||||
| CVE-2024-43655 | 2026-04-15 | N/A | ||
| Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root This issue affects Iocharger firmware for AC model chargers before version 24120701. Likelihood: Moderate – The attacker will first need to find the name of the script, and needs a (low privilege) account to gain access to the script, or convince a user with such access to execute a request to it. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and deletefiles and services. CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y). | ||||
| CVE-2024-43656 | 2026-04-15 | 8.8 High | ||
| Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root This issue affects Iocharger firmware for AC model chargers before version 24120701. Likelihood: Moderate – It might be difficult for an attacker to identify the file structure of the <redated> directory, and then modify the backup to add a new CGI script in the correct directory. Furthermore, the attacker will need an account to restore the settings backup, or convince a user with such access to upload a modified backup file. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and deletefiles and services. CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y). | ||||
| CVE-2024-43657 | 2026-04-15 | 8.8 High | ||
| Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root This issue affects Iocharger firmware for AC model chargers before version 24120701. Likelihood: High. However, the attacker will need a (low privilege) account to gain access to the action.exe CGI binary and upload the crafted firmware file, or convince a user with such access to upload it. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and deletefiles and services. CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y). | ||||
| CVE-2025-14204 | 2026-04-15 | 6.3 Medium | ||
| A vulnerability has been found in TykoDev cherry-studio-TykoFork 0.1. This issue affects the function redirectToAuthorization of the file /.well-known/oauth-authorization-server of the component OAuth Server Discovery. Such manipulation of the argument authorizationUrl leads to os command injection. The attack can be executed remotely. The exploit has been disclosed to the public and may be used. | ||||
| CVE-2025-52573 | 2026-04-15 | 6 Medium | ||
| iOS Simulator MCP Server (ios-simulator-mcp) is a Model Context Protocol (MCP) server for interacting with iOS simulators. Versions prior to 1.3.3 are written in a way that is vulnerable to command injection vulnerability attacks as part of some of its MCP Server tool definition and implementation. The MCP Server exposes the tool `ui_tap` which relies on Node.js child process API `exec` which is an unsafe and vulnerable API if concatenated with untrusted user input. LLM exposed user input for `duration`, `udid`, and `x` and `y` args can be replaced with shell meta-characters like `;` or `&&` or others to change the behavior from running the expected command `idb` to another command. When LLMs are tricked through prompt injection (and other techniques and attack vectors) to call the tool with input that uses special shell characters such as `; rm -rf /tmp;#` and other payload variations, the full command-line text will be interepted by the shell and result in other commands except of `ps` executing on the host running the MCP Server. Version 1.3.3 contains a patch for the issue. | ||||
| CVE-2025-4640 | 2026-04-15 | N/A | ||
| Out-of-bounds Write vulnerability in PointCloudLibrary pcl allows Overflow Buffers. Since version 1.14.0, PCL by default uses a zlib installation from the system, unless the user sets WITH_SYSTEM_ZLIB=FALSE. So this potential vulnerability is only relevant if the PCL version is older than 1.14.0 or the user specifically requests to not use the system zlib. | ||||
| CVE-2025-52379 | 2026-04-15 | 5.4 Medium | ||
| Nexxt Solutions NCM-X1800 Mesh Router firmware UV1.2.7 and below contains an authenticated command injection vulnerability in the firmware update feature. The /web/um_fileName_set.cgi and /web/um_web_upgrade.cgi endpoints fail to properly sanitize the upgradeFileName parameter, allowing authenticated attackers to execute arbitrary OS commands on the device, resulting in remote code execution. | ||||
| CVE-2021-47719 | 1 Commax | 1 Webviewer Activex Control | 2026-04-15 | N/A |
| COMMAX WebViewer ActiveX Control 2.1.4.5 contains a buffer overflow vulnerability that allows attackers to execute arbitrary code by providing excessively long string arrays through multiple functions. Attackers can exploit boundary errors in Commax_WebViewer.ocx to cause buffer overflow conditions and potentially gain code execution. | ||||
| CVE-2021-47705 | 1 Commax | 1 Ums Client Activex Control | 2026-04-15 | N/A |
| COMMAX UMS Client ActiveX Control 1.7.0.2 contains a heap-based buffer overflow vulnerability that allows attackers to execute arbitrary code by providing excessively long string arrays through multiple functions. Attackers can exploit improper boundary validation in CNC_Ctrl.dll to cause heap corruption and potentially gain system-level access. | ||||
| CVE-2025-7771 | 1 Techpowerup | 1 Throttlestop | 2026-04-15 | N/A |
| ThrottleStop.sys, a legitimate driver, exposes two IOCTL interfaces that allow arbitrary read and write access to physical memory via the MmMapIoSpace function. This insecure implementation can be exploited by a malicious user-mode application to patch the running Windows kernel and invoke arbitrary kernel functions with ring-0 privileges. The vulnerability enables local attackers to execute arbitrary code in kernel context, resulting in privilege escalation and potential follow-on attacks, such as disabling security software or bypassing kernel-level protections. ThrottleStop.sys version 3.0.0.0 and possibly others are affected. Apply updates per vendor instructions. | ||||
| CVE-2019-25289 | 1 Inim | 1 Smartliving Smartlan | 2026-04-15 | 8.8 High |
| SmartLiving SmartLAN <=6.x contains an authenticated remote command injection vulnerability in the web.cgi binary through the 'par' POST parameter with the 'testemail' module. Attackers can exploit the unsanitized parameter and system() function call to execute arbitrary system commands with root privileges using default credentials. | ||||
| CVE-2018-25154 | 1 Gnu | 1 Barcode | 2026-04-15 | 9.8 Critical |
| GNU Barcode 0.99 contains a buffer overflow vulnerability in its code 93 encoding process that allows attackers to trigger memory corruption. Attackers can exploit boundary errors during input file processing to potentially execute arbitrary code on the affected system. | ||||
| CVE-2025-6978 | 1 Arista | 1 Ng Firewall | 2026-04-15 | 7.2 High |
| Diagnostics command injection vulnerability | ||||
| CVE-2025-5898 | 1 Gnu | 1 Pspp | 2026-04-15 | 5.3 Medium |
| A vulnerability classified as critical has been found in GNU PSPP 82fb509fb2fedd33e7ac0c46ca99e108bb3bdffb. Affected is the function parse_variables_option of the file utilities/pspp-convert.c. The manipulation leads to out-of-bounds write. The attack needs to be approached locally. The exploit has been disclosed to the public and may be used. | ||||
| CVE-2024-43649 | 2026-04-15 | 8.8 High | ||
| Authenticated command injection in the filename of a <redacted>.exe request leads to remote code execution as the root user. This issue affects Iocharger firmware for AC models before version 24120701. Likelihood: Moderate – This action is not a common place for command injection vulnerabilities to occur. Thus, an attacker will likely only be able to find this vulnerability by reverse-engineering the firmware or trying it on all <redacted> fields. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a payload. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. CVSS clarification: This attack can be performed over any network conenction serving the web interfacr (AV:N), and there are not additional mitigating measures that need to be circumvented (AC:L) or other prerequisites (AT:N). The attack does require privileges, but the level does not matter (PR:L), there is no user interaction required (UI:N). The attack leeds to a full compromised of the charger (VC:H/VI:H/VA:H) and a compromised charger can be used to "pivot" to networks that should normally not be reachable (SC:L/SI:L/SA:H). Because this is an EV chargers with significant pwoer, there is a potential safety imp0act (S:P). THis attack can be automated (AU:Y). | ||||
| CVE-2025-6514 | 2026-04-15 | 9.6 Critical | ||
| mcp-remote is exposed to OS command injection when connecting to untrusted MCP servers due to crafted input from the authorization_endpoint response URL | ||||