Export limit exceeded: 22268 CVEs match your query. Please refine your search to export 10,000 CVEs or fewer.

Search

Search Results (22268 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2012-10040 1 Openfiler 1 Openfiler 2026-04-15 N/A
Openfiler v2.x contains a command injection vulnerability in the system.html page. The device parameter is used to instantiate a NetworkCard object, whose constructor in network.inc calls exec() with unsanitized input. An authenticated attacker can exploit this to execute arbitrary commands as the openfiler user. Due to misconfigured sudoers, the openfiler user can escalate privileges to root via sudo /bin/bash without a password.
CVE-2024-43654 2026-04-15 8.8 High
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability in Iocharger firmware for AC models allows OS Command Injection as root This issue affects all Iocharger AC EV charger models on a firmware version before 25010801. Likelihood: Moderate – The <redacted> binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a crafted HTTP request. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y).
CVE-2024-43655 2026-04-15 N/A
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root This issue affects Iocharger firmware for AC model chargers before version 24120701. Likelihood: Moderate – The attacker will first need to find the name of the script, and needs a (low privilege) account to gain access to the script, or convince a user with such access to execute a request to it. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and deletefiles and services. CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y).
CVE-2024-43656 2026-04-15 8.8 High
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root This issue affects Iocharger firmware for AC model chargers before version 24120701. Likelihood: Moderate – It might be difficult for an attacker to identify the file structure of the <redated> directory, and then modify the backup to add a new CGI script in the correct directory. Furthermore, the attacker will need an account to restore the settings backup, or convince a user with such access to upload a modified backup file. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and deletefiles and services. CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y).
CVE-2024-43657 2026-04-15 8.8 High
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root This issue affects Iocharger firmware for AC model chargers before version 24120701. Likelihood: High. However, the attacker will need a (low privilege) account to gain access to the action.exe CGI binary and upload the crafted firmware file, or convince a user with such access to upload it. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and deletefiles and services. CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y).
CVE-2017-20216 1 Flir 1 Thermal Camera 2026-04-15 9.8 Critical
FLIR Thermal Camera PT-Series firmware version 8.0.0.64 contains multiple unauthenticated remote command injection vulnerabilities in the controllerFlirSystem.php script. Attackers can execute arbitrary system commands as root by exploiting unsanitized POST parameters in the execFlirSystem() function through shell_exec() calls. Exploitation evidence was observed by the Shadowserver Foundation on 2026-01-06 (UTC).
CVE-2019-25289 1 Inim 1 Smartliving Smartlan 2026-04-15 8.8 High
SmartLiving SmartLAN <=6.x contains an authenticated remote command injection vulnerability in the web.cgi binary through the 'par' POST parameter with the 'testemail' module. Attackers can exploit the unsanitized parameter and system() function call to execute arbitrary system commands with root privileges using default credentials.
CVE-2021-47705 1 Commax 1 Ums Client Activex Control 2026-04-15 N/A
COMMAX UMS Client ActiveX Control 1.7.0.2 contains a heap-based buffer overflow vulnerability that allows attackers to execute arbitrary code by providing excessively long string arrays through multiple functions. Attackers can exploit improper boundary validation in CNC_Ctrl.dll to cause heap corruption and potentially gain system-level access.
CVE-2021-47719 1 Commax 1 Webviewer Activex Control 2026-04-15 N/A
COMMAX WebViewer ActiveX Control 2.1.4.5 contains a buffer overflow vulnerability that allows attackers to execute arbitrary code by providing excessively long string arrays through multiple functions. Attackers can exploit boundary errors in Commax_WebViewer.ocx to cause buffer overflow conditions and potentially gain code execution.
CVE-2025-14204 2026-04-15 6.3 Medium
A vulnerability has been found in TykoDev cherry-studio-TykoFork 0.1. This issue affects the function redirectToAuthorization of the file /.well-known/oauth-authorization-server of the component OAuth Server Discovery. Such manipulation of the argument authorizationUrl leads to os command injection. The attack can be executed remotely. The exploit has been disclosed to the public and may be used.
CVE-2025-5943 1 Microdicom 1 Dicom Viewer 2026-04-15 8.8 High
MicroDicom DICOM Viewer suffers from an out-of-bounds write vulnerability. Remote attackers are able to exploit this issue to potentially execute arbitrary code on affected installations of DICOM Viewer. User interaction is required to exploit the vulnerability in that the user must either visit a malicious website or open a malicious DICOM file locally.
CVE-2025-4640 2026-04-15 N/A
Out-of-bounds Write vulnerability in PointCloudLibrary pcl allows Overflow Buffers. Since version 1.14.0, PCL by default uses a zlib installation from the system, unless the user sets WITH_SYSTEM_ZLIB=FALSE. So this potential vulnerability is only relevant if the PCL version is older than 1.14.0 or the user specifically requests to not use the system zlib.
CVE-2025-52379 2026-04-15 5.4 Medium
Nexxt Solutions NCM-X1800 Mesh Router firmware UV1.2.7 and below contains an authenticated command injection vulnerability in the firmware update feature. The /web/um_fileName_set.cgi and /web/um_web_upgrade.cgi endpoints fail to properly sanitize the upgradeFileName parameter, allowing authenticated attackers to execute arbitrary OS commands on the device, resulting in remote code execution.
CVE-2023-51395 1 Silabs 1 Z-wave Software Development Kit 2026-04-15 8.8 High
The vulnerability described by CVE-2023-0972 has been additionally discovered in Silicon Labs Z-Wave end devices. This vulnerability may allow an unauthenticated attacker within Z-Wave range to overflow a stack buffer, leading to arbitrary code execution.
CVE-2025-7771 1 Techpowerup 1 Throttlestop 2026-04-15 N/A
ThrottleStop.sys, a legitimate driver, exposes two IOCTL interfaces that allow arbitrary read and write access to physical memory via the MmMapIoSpace function. This insecure implementation can be exploited by a malicious user-mode application to patch the running Windows kernel and invoke arbitrary kernel functions with ring-0 privileges. The vulnerability enables local attackers to execute arbitrary code in kernel context, resulting in privilege escalation and potential follow-on attacks, such as disabling security software or bypassing kernel-level protections. ThrottleStop.sys version 3.0.0.0 and possibly others are affected. Apply updates per vendor instructions.
CVE-2024-38665 2026-04-15 8.4 High
Out-of-bounds write in some Intel(R) Graphics Drivers may allow an authenticated user to potentially enable escalation of privilege via local access.
CVE-2025-52573 2026-04-15 6 Medium
iOS Simulator MCP Server (ios-simulator-mcp) is a Model Context Protocol (MCP) server for interacting with iOS simulators. Versions prior to 1.3.3 are written in a way that is vulnerable to command injection vulnerability attacks as part of some of its MCP Server tool definition and implementation. The MCP Server exposes the tool `ui_tap` which relies on Node.js child process API `exec` which is an unsafe and vulnerable API if concatenated with untrusted user input. LLM exposed user input for `duration`, `udid`, and `x` and `y` args can be replaced with shell meta-characters like `;` or `&&` or others to change the behavior from running the expected command `idb` to another command. When LLMs are tricked through prompt injection (and other techniques and attack vectors) to call the tool with input that uses special shell characters such as `; rm -rf /tmp;#` and other payload variations, the full command-line text will be interepted by the shell and result in other commands except of `ps` executing on the host running the MCP Server. Version 1.3.3 contains a patch for the issue.
CVE-2024-13089 2026-04-15 7.2 High
An OS command injection vulnerability within the update functionality may allow an authenticated administrator to execute unauthorized arbitrary OS commands. Users with administrative privileges may upload update packages to upgrade the versions of Nozomi Networks Guardian and CMC. While these updates are signed and their signatures are validated prior to installation, an improper signature validation check has been identified. This issue could potentially enable users to execute commands remotely on the appliance, thereby impacting confidentiality, integrity, and availability.
CVE-2023-4856 2026-04-15 8.8 High
A format string vulnerability was identified in SMM/SMM2 and FPC that could allow an authenticated user to execute arbitrary commands on a specific API endpoint.
CVE-2023-4855 2026-04-15 7.2 High
A command injection vulnerability was identified in SMM/SMM2 and FPC that could allow an authenticated user with elevated privileges to execute unauthorized commands via IPMI.