| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| Alarm.com ADC-V522IR 0100b9 devices have Incorrect Access Control, a different issue than CVE-2018-19588. This occurs because of incorrect protection of VPN certificates (used for initiating a VPN session to the Alarm.com infrastructure) on the local camera device. |
| The root password of the Cobham EXPLORER 710 is the same for all versions of firmware up to and including v1.08. This could allow an attacker to reverse-engineer the password from available versions to gain authenticated access to the device. |
| The implementations of EAP-PWD in hostapd and wpa_supplicant are vulnerable to side-channel attacks as a result of cache access patterns. All versions of hostapd and wpa_supplicant with EAP-PWD support are vulnerable. The ability to install and execute applications is necessary for a successful attack. Memory access patterns are visible in a shared cache. Weak passwords may be cracked. Versions of hostapd/wpa_supplicant 2.7 and newer, are not vulnerable to the timing attack described in CVE-2019-9494. Both hostapd with EAP-pwd support and wpa_supplicant with EAP-pwd support prior to and including version 2.7 are affected. |
| The implementations of SAE in hostapd and wpa_supplicant are vulnerable to side channel attacks as a result of observable timing differences and cache access patterns. An attacker may be able to gain leaked information from a side channel attack that can be used for full password recovery. Both hostapd with SAE support and wpa_supplicant with SAE support prior to and including version 2.7 are affected. |
| An issue was discovered on D-Link DIR-825 Rev.B 2.10 devices. The "user" account has a blank password. |
| An issue was discovered on Moxa MGate MB3170 and MB3270 devices before 4.1, MB3280 and MB3480 devices before 3.1, MB3660 devices before 2.3, and MB3180 devices before 2.1. The application's configuration file contains parameters that represent passwords in cleartext. |
| An issue was discovered on Moxa MGate MB3170 and MB3270 devices before 4.1, MB3280 and MB3480 devices before 3.1, MB3660 devices before 2.3, and MB3180 devices before 2.1. Insufficient password requirements for the MGate web application may allow an attacker to gain access by brute-forcing account passwords. |
| Redbrick Shift through 3.4.3 allows an attacker to extract authentication tokens of services (such as Gmail, Outlook, etc.) used in the application. |
| The Simple - Better Banking application 2.45.0 through 2.45.3 (fixed in 2.46.0) for Android was affected by an information disclosure vulnerability that leaked the user's password to the keyboard autocomplete functionality. Third-party Android keyboards that capture the password may store this password in cleartext, or transmit the password to third-party services for keyboard customization purposes. A compromise of any datastore that contains keyboard autocompletion caches would result in the disclosure of the user's Simple Bank password. |
| A weak password vulnerability was discovered in Enphase Envoy R3.*.*. One can login via TCP port 8888 with the admin password for the admin account. |
| An issue was discovered on MOBOTIX S14 MX-V4.2.1.61 devices. /admin/access accepts a request to set the "aaaaa" password, considered insecure for some use cases, from a user. |
| Weak default password cause vulnerability in SonicWall Email Security appliance which leads to attacker gain access to appliance database. This vulnerability affected Email Security Appliance version 10.0.2 and earlier. |
| Artica Proxy 3.06.200056 allows remote attackers to execute arbitrary commands as root by reading the ressources/settings.inc ldap_admin and ldap_password fields, using these credentials at logon.php, and then entering the commands in the admin.index.php command-line field. |
| Nortek Linear eMerge 50P/5000P devices have Default Credentials. |
| Linear eMerge E3-Series devices have Cleartext Credentials in a Database. |
| An information exposure vulnerability in the external authentication profile form of FortiSIEM 5.2.2 and earlier may allow an authenticated attacker to retrieve the external authentication password via the HTML source code. |
| Platform dependent weakness. This issue only impacts iSeries platforms. On these platforms, in BIG-IP (LTM, AAM, AFM, Analytics, APM, ASM, DNS, Edge Gateway, FPS, GTM, Link Controller, PEM, WebAccelerator) versions 14.0.0-14.1.0.1, 13.0.0-13.1.1.3, and 12.1.1 HF2-12.1.4, the secureKeyCapable attribute was not set which causes secure vault to not use the F5 hardware support to store the unit key. Instead the unit key is stored in plaintext on disk as would be the case for Z100 systems. Additionally this causes the unit key to be stored in UCS files taken on these platforms. |
| A vulnerability has been identified in SCALANCE X-200 switch family (incl. SIPLUS NET variants) (All Versions < V5.2.4), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions < V5.5.0), SCALANCE X-300 switch family (incl. X408 and SIPLUS NET variants) (All versions < V4.1.3), SCALANCE X-414-3E (All versions). The affected devices store passwords in a recoverable format. An attacker may extract and recover device passwords from the device configuration. Successful exploitation requires access to a device configuration backup and impacts confidentiality of the stored passwords. |
| In Auto-Maskin RP210E Versions 3.7 and prior, DCU210E Versions 3.7 and prior and Marine Observer Pro (Android App), the software contains a mechanism for users to recover or change their passwords without knowing the original password, but the mechanism is weak. |
| An attacker could retrieve plain-text credentials stored in a XML file on PR100088 Modbus gateway versions prior to Release R02 (or Software Version 1.1.13166) through FTP. |