Search Results (408 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2024-27147 1 Toshibatec 50 E-studio-2010-ac, E-studio-2015-nc, E-studio-2018 A and 47 more 2026-04-15 7.4 High
The Toshiba printers are vulnerable to a Local Privilege Escalation vulnerability. An attacker can remotely compromise any Toshiba printer. As for the affected products/models/versions, see the reference URL.
CVE-2024-27146 1 Toshibatec 50 E-studio-2010-ac, E-studio-2015-nc, E-studio-2018 A and 47 more 2026-04-15 6.7 Medium
The Toshiba printers do not implement privileges separation. As for the affected products/models/versions, see the reference URL.
CVE-2024-21924 2026-04-15 8.2 High
SMM callout vulnerability within the AmdPlatformRasSspSmm driver could allow a ring 0 attacker to modify boot services handlers, potentially resulting in arbitrary code execution.
CVE-2025-24331 2026-04-15 6.4 Medium
The Single RAN baseband OAM service is intended to run as an unprivileged service. However, it initially starts with root privileges and assigns certain capabilities before dropping to an unprivileged level. The capabilities retained from the root period are considered extensive after the privilege drop and, in theory, could potentially allow actions beyond the intended scope of the OAM service. These actions could include gaining root privileges, accessing root-owned files, modifying them as the file owner, and then returning them to root ownership. This issue has been corrected starting from release 24R1-SR 0.2 MP and later. Beginning with release 24R1-SR 0.2 MP, the OAM service software capabilities are restricted to the minimum necessary.
CVE-2025-23395 2026-04-15 7.8 High
Screen 5.0.0 when it runs with setuid-root privileges does not drop privileges while operating on a user supplied path. This allows unprivileged users to create files in arbitrary locations with `root` ownership, the invoking user's (real) group ownership and file mode 0644. All data written to the Screen PTY will be logged into this file, allowing to escalate to root privileges
CVE-2025-23009 1 Sonicwall 1 Netextender 2026-04-15 7.2 High
A local privilege escalation vulnerability in SonicWall NetExtender Windows (32 and 64 bit) client which allows an attacker to trigger an arbitrary file deletion.
CVE-2024-43649 2026-04-15 8.8 High
Authenticated command injection in the filename of a <redacted>.exe request leads to remote code execution as the root user. This issue affects Iocharger firmware for AC models before version 24120701. Likelihood: Moderate – This action is not a common place for command injection vulnerabilities to occur. Thus, an attacker will likely only be able to find this vulnerability by reverse-engineering the firmware or trying it on all <redacted> fields. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a payload. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. CVSS clarification: This attack can be performed over any network conenction serving the web interfacr (AV:N), and there are not additional mitigating measures that need to be circumvented (AC:L) or other prerequisites (AT:N). The attack does require privileges, but the level does not matter (PR:L), there is no user interaction required (UI:N). The attack leeds to a full compromised of the charger (VC:H/VI:H/VA:H) and a compromised charger can be used to "pivot" to networks that should normally not be reachable (SC:L/SI:L/SA:H). Because this is an EV chargers with significant pwoer, there is a potential safety imp0act (S:P). THis attack can be automated (AU:Y).
CVE-2025-23180 2026-04-15 8 High
CWE-250: Execution with Unnecessary Privileges
CVE-2024-6834 2026-04-15 9 Critical
A vulnerability in APIML Spring Cloud Gateway which leverages user privileges by unexpected signing proxied request by Zowe's client certificate. This allows access to a user to the endpoints requiring an internal client certificate without any credentials. It could lead to managing components in there and allow an attacker to handle the whole communication including user credentials.
CVE-2025-13375 1 Ibm 1 Common Cryptographic Architecture 2026-04-15 9.8 Critical
IBM Common Cryptographic Architecture (CCA) 7.5.52 and 8.4.82 could allow an unauthenticated user to execute arbitrary commands with elevated privileges on the system.
CVE-2024-22017 2 Nodejs, Redhat 2 Nodejs, Enterprise Linux 2026-04-15 7.3 High
setuid() does not affect libuv's internal io_uring operations if initialized before the call to setuid(). This allows the process to perform privileged operations despite presumably having dropped such privileges through a call to setuid(). This vulnerability affects all users using version greater or equal than Node.js 18.18.0, Node.js 20.4.0 and Node.js 21.
CVE-2025-23008 1 Sonicwall 1 Netextender 2026-04-15 7.2 High
An improper privilege management vulnerability in the SonicWall NetExtender Windows (32 and 64 bit) client allows a low privileged attacker to modify configurations.
CVE-2025-22368 2026-04-15 N/A
The authenticated SCU firmware command of the firmware for Mennekes Smart / Premium Chargingpoints can be abused for command execution because OS commands are improperly neutralized when certain fields are passed to the underlying OS.
CVE-2025-6894 1 Moxa 7 Edf-g1002-bp, Edr-8010, Edr-g9010 and 4 more 2026-04-15 N/A
An Execution with Unnecessary Privileges vulnerability has been identified in Moxa’s network security appliances and routers. A flaw in the API authorization logic of the affected device allows an authenticated, low-privileged user to execute the administrative `ping` function, which is restricted to higher-privileged roles. This vulnerability enables the user to perform internal network reconnaissance, potentially discovering internal hosts or services that would otherwise be inaccessible. Repeated exploitation could lead to minor resource consumption. While the overall impact is limited, it may result in some loss of confidentiality and availability on the affected device. There is no impact on the integrity of the device, and the vulnerability does not affect any subsequent systems.
CVE-2025-22367 2026-04-15 N/A
The authenticated time setting capability of the firmware for Mennekes Smart / Premium Chargingpoints can be abused for command execution because OS command are improperly neutralized when certain fields are passed to the underlying OS.
CVE-2025-23181 2026-04-15 8 High
CWE-250: Execution with Unnecessary Privileges
CVE-2024-43652 2026-04-15 8.8 High
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root This issue affects Iocharger firmware for AC model chargers before version 24120701 Likelihood: Moderate – The <redacted> binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a crafted HTTP request. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services.
CVE-2024-43648 2026-04-15 8.8 High
Command injection in the <redacted> parameter of a <redacted>.exe request leads to remote code execution as the root user. This issue affects Iocharger firmware for AC models before version 24120701. Likelihood: Moderate – This action is not a common place for command injection vulnerabilities to occur. Thus, an attacker will likely only be able to find this vulnerability by reverse-engineering the firmware or trying it on all <redacted> fields. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a payload. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. CVSS clarification. The attack can be executed over any network connection the station is listening to and serves the web interface (AV:N), and there are no additional security measure sin place that need to be circumvented (AC:L), the attack does not rely on preconditions (AT:N). The attack does require authentication, but the level of authentication is irrelevant (PR:L), it does not require user interaction (UI:N). If is a full system compromise, potentially fully compromising confidentiality, integrity and availability of the devicer (VC:H/VI:H/VA:H).  A compromised charger can be used to "pivot" onto networks that should otherwise be closed, cause a low confidentiality and interity impact on subsequent systems. (SC:L/SI:L/SA:H). Because this device is an EV charger handing significant amounts of power, we suspect this vulnerability can have a safety impact (S:P). The attack can be automated (AU:Y).
CVE-2025-6949 1 Moxa 7 Edf-g1002-bp, Edr-8010, Edr-g9010 and 4 more 2026-04-15 N/A
An Execution with Unnecessary Privileges vulnerability has been identified in Moxa’s network security appliances and routers. A critical authorization flaw in the API allows an authenticated, low-privileged user to create a new administrator account, including accounts with usernames identical to existing users. In certain scenarios, this vulnerability could allow an attacker to gain full administrative control over the affected device, leading to potential account impersonation. While successful exploitation can severely impact the confidentiality, integrity, and availability of the affected device itself, there is no loss of confidentiality or integrity within any subsequent systems.
CVE-2024-3498 2026-04-15 7.8 High
Attackers can then execute malicious files by enabling certain services of the printer via the web configuration page and elevate its privileges to root. As for the affected products/models/versions, see the reference URL.