Export limit exceeded: 380706 CVEs match your query. Please refine your search to export 10,000 CVEs or fewer.
Search
Search Results (380706 CVEs found)
| CVE | Vendors | Products | Updated | CVSS v3.1 |
|---|---|---|---|---|
| CVE-2024-41228 | 1 Symlink | 1 Symlink | 2026-04-15 | 7.6 High |
| A symlink following vulnerability in the pouch cp function of AliyunContainerService pouch v1.3.1 allows attackers to escalate privileges and write arbitrary files. | ||||
| CVE-2024-43688 | 2 Openbsd, Vixie | 2 Openbsd, Cron | 2026-04-15 | 7.3 High |
| cron/entry.c in vixie cron before 9cc8ab1, as used in OpenBSD 7.4 and 7.5, allows a heap-based buffer underflow and memory corruption. NOTE: this issue was introduced during a May 2023 refactoring. | ||||
| CVE-2024-43647 | 1 Siemens | 14 Simatic S7-200 Smart Cpu Cr20s, Simatic S7-200 Smart Cpu Cr30s, Simatic S7-200 Smart Cpu Cr40 and 11 more | 2026-04-15 | 7.5 High |
| A vulnerability has been identified in SIMATIC S7-200 SMART CPU CR40 (6ES7288-1CR40-0AA0) (All versions), SIMATIC S7-200 SMART CPU CR60 (6ES7288-1CR60-0AA0) (All versions), SIMATIC S7-200 SMART CPU SR20 (6ES7288-1SR20-0AA0) (All versions), SIMATIC S7-200 SMART CPU SR20 (6ES7288-1SR20-0AA1) (All versions), SIMATIC S7-200 SMART CPU SR30 (6ES7288-1SR30-0AA0) (All versions), SIMATIC S7-200 SMART CPU SR30 (6ES7288-1SR30-0AA1) (All versions), SIMATIC S7-200 SMART CPU SR40 (6ES7288-1SR40-0AA0) (All versions), SIMATIC S7-200 SMART CPU SR40 (6ES7288-1SR40-0AA1) (All versions), SIMATIC S7-200 SMART CPU SR60 (6ES7288-1SR60-0AA0) (All versions), SIMATIC S7-200 SMART CPU SR60 (6ES7288-1SR60-0AA1) (All versions), SIMATIC S7-200 SMART CPU ST20 (6ES7288-1ST20-0AA0) (All versions), SIMATIC S7-200 SMART CPU ST20 (6ES7288-1ST20-0AA1) (All versions), SIMATIC S7-200 SMART CPU ST30 (6ES7288-1ST30-0AA0) (All versions), SIMATIC S7-200 SMART CPU ST30 (6ES7288-1ST30-0AA1) (All versions), SIMATIC S7-200 SMART CPU ST40 (6ES7288-1ST40-0AA0) (All versions), SIMATIC S7-200 SMART CPU ST40 (6ES7288-1ST40-0AA1) (All versions), SIMATIC S7-200 SMART CPU ST60 (6ES7288-1ST60-0AA0) (All versions), SIMATIC S7-200 SMART CPU ST60 (6ES7288-1ST60-0AA1) (All versions). Affected devices do not properly handle TCP packets with an incorrect structure. This could allow an unauthenticated remote attacker to cause a denial of service condition. To restore normal operations, the network cable of the device needs to be unplugged and re-plugged. | ||||
| CVE-2024-43648 | 2026-04-15 | 8.8 High | ||
| Command injection in the <redacted> parameter of a <redacted>.exe request leads to remote code execution as the root user. This issue affects Iocharger firmware for AC models before version 24120701. Likelihood: Moderate – This action is not a common place for command injection vulnerabilities to occur. Thus, an attacker will likely only be able to find this vulnerability by reverse-engineering the firmware or trying it on all <redacted> fields. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a payload. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. CVSS clarification. The attack can be executed over any network connection the station is listening to and serves the web interface (AV:N), and there are no additional security measure sin place that need to be circumvented (AC:L), the attack does not rely on preconditions (AT:N). The attack does require authentication, but the level of authentication is irrelevant (PR:L), it does not require user interaction (UI:N). If is a full system compromise, potentially fully compromising confidentiality, integrity and availability of the devicer (VC:H/VI:H/VA:H). A compromised charger can be used to "pivot" onto networks that should otherwise be closed, cause a low confidentiality and interity impact on subsequent systems. (SC:L/SI:L/SA:H). Because this device is an EV charger handing significant amounts of power, we suspect this vulnerability can have a safety impact (S:P). The attack can be automated (AU:Y). | ||||
| CVE-2024-43652 | 2026-04-15 | 8.8 High | ||
| Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root This issue affects Iocharger firmware for AC model chargers before version 24120701 Likelihood: Moderate – The <redacted> binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a crafted HTTP request. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. | ||||
| CVE-2024-43658 | 2026-04-15 | N/A | ||
| Patch traversal, External Control of File Name or Path vulnerability in Iocharger Home allows deletion of arbitrary files This issue affects Iocharger firmware for AC model before firmware version 25010801. Likelihood: High, but requires authentication Impact: Critical – The vulnerability can be used to delete any file on the charging station, severely impacting the integrity of the charging station. Furthermore, the vulnerability could be used to delete binaries required for the functioning of the charging station, severely impacting the availability of the charging station. CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads compromised of the integrity and availability of the device (VVC:N/VI:H/VA:H), with no effect on subsequent systems (SC:N/SI:N/SA:N). We do not forsee a safety impact (S:N). This attack can be automated (AU:Y). | ||||
| CVE-2024-43659 | 2026-04-15 | 7.2 High | ||
| After gaining access to the firmware of a charging station, a file at <redacted> can be accessed to obtain default credentials that are the same across all Iocharger AC model EV chargers. This issue affects Iocharger firmware for AC models before firmware version 25010801. The issue is addressed by requiring a mandatory password change on first login, it is still recommended to change the password on older models. Likelihood: Moderate – The attacker will first have to abuse a code execution or file inclusion vulnerability (for example by using <redacted>.sh) to gain access to the <redacted>.json file, or obtain a firmware dump of the charging station or obtain the firmware via other channels. Impact: Critical – All chargers using Iocharger firmware for AC models started with the same initial password. For models with firmware version before 25010801 a password change was not mandatory. It is therefore very likely that this firmware password is still active on many chargers. These credentials could, once obtained, allow an attacker to log into many Iocharger charging station, and allow them to execute arbitrary commands via the System → Custom page. CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, and requires high privileges (PR:H), there is no user interaction required (UI:N). The attack leads to a compromised of the confidentialy of the "super user" credentials of the device (VC:H/VI:N/VA:N), and can subsequently be used to full compromise and other devices (SC:H/SI:H/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y). | ||||
| CVE-2024-43662 | 2026-04-15 | N/A | ||
| The <redacted>.exe or <redacted>.exe CGI binary can be used to upload arbitrary files to /tmp/upload/ or /tmp/ respectively as any user, although the user interface for uploading files is only shown to the iocadmin user. This issue affects Iocharger firmware for AC models before version 24120701. Likelihood: Moderate – An attacker will need to have knowledge of this CGI binary, e.g. by finding it in firmware. Furthermore, the attacker will need a (low privilege) account to gain access to the <redacted>.exe or <redacted>.exe CGI binary and upload the file, or convince a user with such access to upload it. Impact: Low – The attacker can upload arbitrary files to /tmp/upload/ or /tmp/. However, the attacker is unable to access or use these files without other vulnerabilities. CVSS clarification. The attack can be executed over any network connection the station is listening to and serves the web interface (AV:N), and there are no additional security measure sin place that need to be circumvented (AC:L), the attack does not rely on preconditions (AT:N). The attack does require authentication, but the level of authentication is irrelevant (PR:L), it does not require user interaction (UI:N). Artitrary files can be uploaded, be these files will not be in a location where they can influence confidentiality or availability and have a minimal impact on device integrity (VC:N/VI:L/VA:N). There is no impact on subsequent systems. (SC:N/SI:N/SA:N). While this device is an EV charger handing significant amounts of power, we do not expect this vulnerability to have a safety impact. The attack can be automated (AU:Y). | ||||
| CVE-2024-43663 | 2026-04-15 | 9.8 Critical | ||
| There are many buffer overflow vulnerabilities present in several CGI binaries of the charging station.This issue affects Iocharger firmware for AC model chargers beforeversion 24120701. Likelihood: High – Given the prevalence of these buffer overflows, and the clear error message of the web server, an attacker is very likely to be able to find these vulnerabilities. Impact: Low – Usually, overflowing one of these buffers just causes a segmentation fault of the CGI binary, which causes the web server to return a 502 Bad Gateway error. However the webserver itself is not affected, and no DoS can be achieved. Abusing these buffer overflows in a meaningful way requires highly technical knowledge, especially since ASLR also seems to be enabled on the charging station. However, a skilled attacker might be able to use one of these buffer overflows to obtain remote code execution. CVSS clarification. The attack can be executed over any network connection the station is listening to and serves the web interface (AV:N), and there are no additional security measure sin place that need to be circumvented (AC:L), the attack does not rely on preconditions (AT:N). The attack does require authentication, but the level of authentication is irrelevant (PR:L), it does not require user interaction (UI:N). The attack has a small impact on the availability of the device (VC:N/VI:N/VA:L). There is no impact on subsequent systems. (SC:N/SI:N/SA:N). While this device is an EV charger handing significant amounts of power, we do not expect this vulnerability to have a safety impact. The attack can be automated (AU:Y). | ||||
| CVE-2024-43690 | 1 Gallagher | 1 Command Centre | 2026-04-15 | 8 High |
| Inclusion of Functionality from Untrusted Control Sphere(CWE-829) in the Command Centre Server and Workstations may allow an attacker to perform Remote Code Execution (RCE). This issue affects: Command Centre Server and Command Centre Workstations 9.10 prior to vEL9.10.1530 (MR2), 9.00 prior to vEL9.00.2168 (MR4), 8.90 prior to vEL8.90.2155 (MR5), 8.80 prior to vEL8.80.1938 (MR6), all versions of 8.70 and prior. | ||||
| CVE-2024-43698 | 1 Kieback\&peter | 10 Ddc4002 Firmware, Ddc4002e Firmware, Ddc4020e Firmware and 7 more | 2026-04-15 | 9.8 Critical |
| Kieback & Peter's DDC4000 series uses weak credentials, which may allow an unauthenticated attacker to get full admin rights on the system. | ||||
| CVE-2024-43701 | 1 Imaginationtech | 1 Graphics Ddk | 2026-04-15 | 7.8 High |
| Software installed and run as a non-privileged user may conduct GPU system calls to read and write freed physical memory from the GPU. | ||||
| CVE-2024-43704 | 1 Imaginationtech | 1 Ddk | 2026-04-15 | 8.4 High |
| Software installed and run as a non-privileged user may conduct improper GPU system calls to gain access to the graphics buffers of a parent process. | ||||
| CVE-2024-41981 | 1 Siemens | 1 Simcenter Nastran | 2026-04-15 | 7.8 High |
| A vulnerability has been identified in Simcenter Femap V2306 (All versions), Simcenter Femap V2401 (All versions), Simcenter Femap V2406 (All versions). The affected application is vulnerable to heap-based buffer overflow while parsing specially crafted BDF files. This could allow an attacker to execute code in the context of the current process. | ||||
| CVE-2024-41972 | 2026-04-15 | 6.5 Medium | ||
| A low privileged remote attacker can overwrite an arbitrary file on the filesystem which may lead to an arbitrary file read with root privileges. | ||||
| CVE-2024-41961 | 1 Sapcc | 1 Elektra | 2026-04-15 | 9.2 Critical |
| Elektra is an opinionated Openstack Dashboard for Operators and Consumers of Openstack Services. A code injection vulnerability was found in the live search functionality of the Ruby on Rails based Elektra web application. An authenticated user can craft a search term containing Ruby code, which later flows into an `eval` sink which executes the code. Fixed in commit 8bce00be93b95a6512ff68fe86bf9554e486bc02. | ||||
| CVE-2024-41956 | 1 Charmbracelet | 1 Soft-serve | 2026-04-15 | 8.1 High |
| Soft Serve is a self-hostable Git server for the command line. Prior to 0.7.5, it is possible for a user who can commit files to a repository hosted by Soft Serve to execute arbitrary code via environment manipulation and Git. The issue is that Soft Serve passes all environment variables given by the client to git subprocesses. This includes environment variables that control program execution, such as LD_PRELOAD. This vulnerability is fixed in 0.7.5. | ||||
| CVE-2024-41951 | 2026-04-15 | 4.4 Medium | ||
| Pheonix App is a Python application designed to streamline various tasks, from managing files to playing mini-games. The issue is that the map of encoding/decoding languages are visible in code. The Problem was patched in 0.2.4. | ||||
| CVE-2024-41950 | 1 Deepset | 1 Haystack | 2026-04-15 | 7.5 High |
| Haystack is an end-to-end LLM framework that allows you to build applications powered by LLMs, Transformer models, vector search and more. Haystack clients that let their users create and run Pipelines from scratch are vulnerable to remote code executions. Certain Components in Haystack use Jinja2 templates, if anyone can create and render that template on the client machine they run any code. The vulnerability has been fixed with Haystack `2.3.1`. | ||||
| CVE-2024-41945 | 2026-04-15 | 3.1 Low | ||
| fuels-ts is a library for interacting with Fuel v2. The typescript SDK has no awareness of to-be-spent transactions causing some transactions to fail or silently get pruned as they are funded with already used UTXOs. The problem occurs, because the `fund` function in `fuels-ts/packages/account/src/account.ts` gets the needed ressources statelessly with the function `getResourcesToSpend` without taking into consideration already used UTXOs. This issue will lead to unexpected SDK behaviour, such as a transaction not getting included in the `txpool` / in a block or a previous transaction silently getting removed from the `txpool` and replaced with a new one. | ||||