| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| Procom NetFORCE 800 4.02 M10 Build 20 and possibly other versions sends the NIS password map (passwd.nis) as a file attachment in diagnostic e-mail messages, which allows remote attackers to obtain the cleartext NIS password hashes. |
| DameWare Mini Remote Control 3.x before 3.74 and 4.x before 4.2 transmits the Blowfish encryption key in plaintext, which allows remote attackers to gain sensitive information. |
| pam_ldap and nss_ldap, when used with OpenLDAP and connecting to a slave using TLS, does not use TLS for the subsequent connection if the client is referred to a master, which may cause a password to be sent in cleartext and allows remote attackers to sniff the password. |
| The Network Attached Storage (NAS) Administration Web Page for Iomega NAS A300U transmits passwords in cleartext, which allows remote attackers to sniff the administrative password. |
| ** UNSUPPORTED WHEN ASSIGNED ** This vulnerability exists in D3D Security IP Camera D8801 due to usage of weak authentication scheme of the HTTP header protocol where authorization tag contain a Base-64 encoded username and password. A remote attacker could exploit this vulnerability by crafting a HTTP packet leading to exposure of user credentials of the targeted device. NOTE: This vulnerability only affects products that are no longer supported by the maintainer. |
| A protocol flaw vulnerability exists in the Xiaomi Mi Connect Service APP. The vulnerability is caused by the validation logic is flawed and can be exploited by attackers to leak sensitive user information. |
| Cleartext Transmission of Sensitive Information vulnerability in Crestron Automate VX allows Sniffing Network Traffic.
The device allows Web UI and API access over non-secure network ports which exposes sensitive information such as user passwords.
This issue affects Automate VX: from 5.6.8161.21536 through 6.4.0.49. |
| CWE-319: Cleartext Transmission of Sensitive Information vulnerability exists that could result in the exposure
of data when network traffic is being sniffed by an attacker. |
| Puncia is the Official CLI utility for Subdomain Center & Exploit Observer. `API_URLS` is utilizing HTTP instead of HTTPS for communication that can lead to issues like Eavesdropping, Data Tampering, Unauthorized Data Access & MITM Attacks. This issue has been addressed in release version 0.21 by using https rather than http connections. All users are advised to upgrade. There is no known workarounds for this vulnerability.
|
| DuraComm SPM-500 DP-10iN-100-MU
transmits sensitive data without encryption over a channel that could be intercepted by attackers. |
| Due to an unsecure default configuration HTTP is used instead of HTTPS for the web interface. An unauthenticated attacker on the same network could exploit this to learn sensitive data during transmission. |
| Aikaan IoT management platform v3.25.0325-5-g2e9c59796 sends a newly generated password to users in plaintext via email and also includes the same password as a query parameter in the account activation URL (e.g., https://domain.com/activate=xyz). This practice can result in password exposure via browser history, proxy logs, referrer headers, and email caching. The vulnerability impacts user credential confidentiality during initial onboarding. |
| YugabyteDB diagnostic information was transmitted over HTTP, which could expose sensitive data during transmission |
| General Industrial Controls Lynx+ Gateway is vulnerable to a cleartext transmission vulnerability that could allow
an attacker to observe network traffic to obtain sensitive information,
including plaintext credentials. |
| The MOD3 command traffic between the monitoring application and the
inverter is transmitted in plaintext without encryption or obfuscation.
This vulnerability may allow an attacker with access to a local network
to intercept, manipulate, replay, or forge critical data, including
read/write operations for voltage, current, and power configuration,
operational status, alarms, telemetry, system reset, or inverter control
commands, potentially disrupting power generation or reconfiguring
inverter settings. |
| Kaleris NAVIS N4 ULC (Ultra Light Client) communicates insecurely using zlib-compressed data over HTTP. An attacker capable of observing network traffic between Ultra Light Clients and N4 servers can extract sensitive information, including plaintext credentials. |
| This vulnerability exists in Digisol DG-GR6821AC Router due to cleartext transmission of credentials in its web management interface. A remote attacker could exploit this vulnerability by intercepting the network traffic and capturing cleartext credentials.
Successful exploitation of this vulnerability could allow the attacker to gain unauthorized access to the targeted device. |
| A vulnerability was detected in LionCoders SalePro POS up to 5.5.0. This issue affects some unknown processing of the component Login. Performing manipulation results in cleartext transmission of sensitive information. The attack can be initiated remotely. The attack is considered to have high complexity. The exploitability is assessed as difficult. The exploit is now public and may be used. The vendor was contacted early about this disclosure but did not respond in any way. |
| A cleartext transmission of sensitive information vulnerability in the affected products allows an unauthorized remote attacker to gain login credentials and access the Web-UI. |
| When using domain users as BRAIN2 users, communication with Active Directory services is unencrypted. This can lead to the interception of authentication data and compromise confidentiality. |