Export limit exceeded: 380706 CVEs match your query. Please refine your search to export 10,000 CVEs or fewer.
Search
Search Results (818 CVEs found)
| CVE | Vendors | Products | Updated | CVSS v3.1 |
|---|---|---|---|---|
| CVE-2025-9996 | 1 Schneider-electric | 1 Blmon | 2026-04-15 | N/A |
| CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability exists that could cause the execution of any shell command when executing a netstat command using BLMon Console in an SSH session. | ||||
| CVE-2025-9997 | 1 Schneider-electric | 1 Blmon | 2026-04-15 | N/A |
| CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability exists that could cause command injection in BLMon that is executed in the operating system console when in a SSH session. | ||||
| CVE-2025-5296 | 1 Schneider-electric | 1 Software Update Utility | 2026-04-15 | 7.3 High |
| CWE-59: Improper Link Resolution Before File Access ('Link Following') vulnerability exists that could cause arbitrary data to be written to protected locations, potentially leading to escalation of privilege, arbitrary file corruption, exposure of application and system information or persistent denial of service when a low-privileged attacker tampers with the installation folder. | ||||
| CVE-2025-13905 | 1 Schneider-electric | 2 Ecostruxure Process Expert, Ecostruxure Process Expert For Aveva System Platform | 2026-04-15 | N/A |
| CWE-276: Incorrect Default Permissions vulnerability exists that could cause privilege escalation through the reverse shell when one or more executable service binaries are modified in the installation folder by a local user with normal privilege upon service restart. | ||||
| CVE-2024-8933 | 1 Schneider-electric | 3 Modicon M340, Modicon Mc80, Modicon Momentum Unity M1e Processor | 2026-04-15 | 7.5 High |
| CWE-924: Improper Enforcement of Message Integrity During Transmission in a Communication Channel vulnerability exists that could cause retrieval of password hash that could lead to denial of service and loss of confidentiality and integrity of controllers. To be successful, the attacker needs to inject themself inside the logical network while a valid user uploads or downloads a project file into the controller. | ||||
| CVE-2025-54926 | 1 Schneider-electric | 2 Ecostruxure Power Monitoring Expert, Ecostruxure Power Operation With Advanced Reports | 2026-04-15 | 7.2 High |
| CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists that could cause remote code execution when an authenticated attacker with admin privileges uploads a malicious file over HTTP which then gets executed. | ||||
| CVE-2025-8449 | 1 Schneider-electric | 3 Ecostruxure Building Operation Enterprise Server, Ecostruxure Enterprise Server, Ecostruxure Workstation | 2026-04-15 | N/A |
| CWE-400: Uncontrolled Resource Consumption vulnerability exists that could cause a denial of service when an authenticated user sends a specially crafted request to a specific endpoint from within the BMS network. | ||||
| CVE-2025-54924 | 1 Schneider-electric | 2 Ecostruxure Power Monitoring Expert, Ecostruxure Power Operation With Advanced Reports | 2026-04-15 | 7.5 High |
| CWE-918: Server-Side Request Forgery (SSRF) vulnerability exists that could cause unauthorized access to sensitive data when an attacker sends a specially crafted document to a vulnerable endpoint. | ||||
| CVE-2025-11565 | 1 Schneider-electric | 1 Powerchute Serial Shutdown | 2026-04-15 | N/A |
| CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists that could cause elevated system access when a Web Admin user on the local network tampers with the POST /REST/UpdateJRE request payload. | ||||
| CVE-2025-54925 | 1 Schneider-electric | 2 Ecostruxure Power Monitoring Expert, Ecostruxure Power Operation With Advanced Reports | 2026-04-15 | 7.5 High |
| CWE-918: Server-Side Request Forgery (SSRF) vulnerability exists that could cause unauthorized access to sensitive data when an attacker configures the application to access a malicious url. | ||||
| CVE-2025-54927 | 1 Schneider-electric | 2 Ecostruxure Power Monitoring Expert, Ecostruxure Power Operation With Advanced Reports | 2026-04-15 | 4.9 Medium |
| CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists that could cause unauthorized access to sensitive files when an authenticated attackers uses a crafted path input that is processed by the system. | ||||
| CVE-2024-9002 | 1 Schneider-electric | 1 Easergy Studio | 2026-04-15 | 7.8 High |
| CWE-269: Improper Privilege Management vulnerability exists that could cause unauthorized access, loss of confidentiality, integrity, and availability of the workstation when non-admin authenticated user tries to perform privilege escalation by tampering with the binaries | ||||
| CVE-2024-8935 | 1 Schneider-electric | 3 Modicon M340 Bmxp341000, Modicon Mc80 Bmkc8020301, Modicon Momentum Unity M1e Processor | 2026-04-15 | 7.5 High |
| CWE-290: Authentication Bypass by Spoofing vulnerability exists that could cause a denial of service and loss of confidentiality and integrity of controllers when conducting a Man-In-The-Middle attack between the controller and the engineering workstation while a valid user is establishing a communication session. This vulnerability is inherent to Diffie Hellman algorithm which does not protect against Man-In-The-Middle attacks. | ||||
| CVE-2025-11566 | 1 Schneider-electric | 1 Powerchute Serial Shutdown | 2026-04-15 | N/A |
| CWE-307: Improper Restriction of Excessive Authentication Attempts vulnerability exists that would allow an attacker on the local network to gain access to the user account by performing an arbitrary number of authentication attempts with different credentials on the /REST/shutdownnow endpoint. | ||||
| CVE-2024-8938 | 1 Schneider-electric | 3 Modicon M340, Modicon Mc80, Modicon Momentum Unity M1e Processor | 2026-04-15 | 8.1 High |
| CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists that could cause a potential arbitrary code execution after a successful Man-In-The-Middle attack followed by sending a crafted Modbus function call to tamper with memory area involved in memory size computation. | ||||
| CVE-2024-8936 | 1 Schneider-electric | 1 Modicon M340 | 2026-04-15 | 6.5 Medium |
| CWE-20: Improper Input Validation vulnerability exists that could lead to loss of confidentiality of controller memory after a successful Man-In-The-Middle attack followed by sending a crafted Modbus function call used to tamper with memory. | ||||
| CVE-2025-7746 | 1 Schneider-electric | 1 Altivar | 2026-04-15 | N/A |
| CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists that could cause an unvalidated data injected by a malicious user potentially leading to modify or read data in a victim’s browser. | ||||
| CVE-2025-11567 | 1 Schneider-electric | 1 Powerchute Serial Shutdown | 2026-04-15 | N/A |
| CWE-276: Incorrect Default Permissions vulnerability exists that could cause elevated system access when the target installation folder is not properly secured. | ||||
| CVE-2025-54923 | 1 Schneider-electric | 2 Ecostruxure Power Monitoring Expert, Ecostruxure Power Operation With Advanced Reports | 2026-04-15 | N/A |
| CWE-502: Deserialization of Untrusted Data vulnerability exists that could cause remote code execution and compromise of system integrity when authenticated users send crafted data to a network-exposed service that performs unsafe deserialization. | ||||
| CVE-2024-6918 | 1 Schneider-electric | 1 Accutech Manager | 2026-04-15 | 7.5 High |
| CWE-120: Buffer Copy without Checking Size of Input ('Classic Buffer Overflow') vulnerability exists that could cause a crash of the Accutech Manager when receiving a specially crafted request over port 2536/TCP. | ||||