| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| A persistent cross-site scripting vulnerability in the graphical user interface of ScreenOS may allow a remote authenticated user to inject web script or HTML and steal sensitive data and credentials from a web administration session, possibly tricking a follow-on administrative user to perform administrative actions on the device. Affected releases are Juniper Networks ScreenOS 6.3.0 versions prior to 6.3.0r26. |
| A persistent cross-site scripting vulnerability in the UI framework used by Junos Space Security Director may allow authenticated users to inject persistent and malicious scripts. This may allow stealing of information or performing actions as a different user when other users access the Security Director web interface. This issue affects all versions of Juniper Networks Junos Space Security Director prior to 17.2R2. |
| A reflected cross-site scripting vulnerability in OpenNMS included with Juniper Networks Junos Space may allow the stealing of sensitive information or session credentials from Junos Space administrators or perform administrative actions. This issue affects Juniper Networks Junos Space versions prior to 18.2R1. |
| Juniper Networks Contrail Service Orchestration releases prior to 3.3.0 use hardcoded credentials to access Keystone service. These credentials allow network based attackers unauthorized access to information stored in keystone. |
| Juniper Networks Contrail Service Orchestrator versions prior to 4.0.0 use hardcoded cryptographic certificates and keys in some cases, which may allow network based attackers to gain unauthorized access to services. |
| Juniper Networks Contrail Service Orchestration releases prior to 4.0.0 have Grafana service enabled by default with hardcoded credentials. These credentials allow network based attackers unauthorized access to information stored in Grafana or exploit other weaknesses or vulnerabilities in Grafana. |
| Juniper Networks Contrail Service Orchestration releases prior to 3.3.0 have Cassandra service enabled by default with hardcoded credentials. These credentials allow network based attackers unauthorized access to information stored in Cassandra. |
| A reflected cross site scripting (XSS) vulnerability in Junos Space may potentially allow a remote authenticated user to inject web script or HTML and steal sensitive data and credentials from a session, and to perform administrative actions on the Junos Space network management device. |
| An unauthenticated network-based attacker able to send a maliciously crafted LLDP packet to the local segment, through a local segment broadcast, may be able to cause a Junos device to enter an improper boundary check condition allowing a memory corruption to occur, leading to a denial of service. Further crafted packets may be able to sustain the denial of service condition. Score: 6.5 MEDIUM (CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H) Further, if the attacker is authenticated on the target device receiving and processing the malicious LLDP packet, while receiving the crafted packets, the attacker may be able to perform command or arbitrary code injection over the target device thereby elevating their permissions and privileges, and taking control of the device. Score: 7.8 HIGH (CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H) An unauthenticated network-based attacker able to send a maliciously crafted LLDP packet to one or more local segments, via LLDP proxy / tunneling agents or other LLDP through Layer 3 deployments, through one or more local segment broadcasts, may be able to cause multiple Junos devices to enter an improper boundary check condition allowing a memory corruption to occur, leading to multiple distributed Denials of Services. These Denials of Services attacks may have cascading Denials of Services to adjacent connected devices, impacts network devices, servers, workstations, etc. Further crafted packets may be able to sustain these Denials of Services conditions. Score 6.8 MEDIUM (CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:C/C:N/I:N/A:H) Further, if the attacker is authenticated on one or more target devices receiving and processing these malicious LLDP packets, while receiving the crafted packets, the attacker may be able to perform command or arbitrary code injection over multiple target devices thereby elevating their permissions and privileges, and taking control multiple devices. Score: 7.8 HIGH (CVSS:3.0/AV:L/AC:H/PR:L/UI:N/S:C/C:H/I:H/A:H) Affected releases are Juniper Networks Junos OS: 12.1X46 versions prior to 12.1X46-D71; 12.3 versions prior to 12.3R12-S7; 12.3X48 versions prior to 12.3X48-D55; 14.1 versions prior to 14.1R8-S5, 14.1R9; 14.1X53 versions prior to 14.1X53-D46, 14.1X53-D50, 14.1X53-D107; 14.2 versions prior to 14.2R7-S9, 14.2R8; 15.1 versions prior to 15.1F2-S17, 15.1F5-S8, 15.1F6-S8, 15.1R5-S7, 15.1R7; 15.1X49 versions prior to 15.1X49-D90; 15.1X53 versions prior to 15.1X53-D65; 16.1 versions prior to 16.1R4-S6, 16.1R5; 16.1X65 versions prior to 16.1X65-D45; 16.2 versions prior to 16.2R2; 17.1 versions prior to 17.1R2. No other Juniper Networks products or platforms are affected by this issue. |
| A high rate of VLAN authentication attempts sent from an adjacent host on the local broadcast domain can trigger high memory utilization by the BBE subscriber management daemon (bbe-smgd), and lead to a denial of service condition. The issue was caused by attempting to process an unbounded number of pending VLAN authentication requests, leading to excessive memory allocation. This issue only affects devices configured for DHCPv4/v6 over AE auto-sensed VLANs, utilized in Broadband Edge (BBE) deployments. Other configurations are unaffected by this issue. Affected releases are Juniper Networks Junos OS: 15.1 versions prior to 15.1R6-S2, 15.1R7; 16.1 versions prior to 16.1R5-S1, 16.1R6; 16.2 versions prior to 16.2R2-S2, 16.2R3; 17.1 versions prior to 17.1R2-S5, 17.1R3; 17.2 versions prior to 17.2R2. |
| QFX and EX Series switches configured to drop traffic when the MAC move limit is exceeded will forward traffic instead of dropping traffic. This can lead to denials of services or other unintended conditions. Affected releases are Juniper Networks Junos OS: 14.1X53 versions prior to 14.1X53-D40; 15.1X53 versions prior to 15.1X53-D55; 15.1 versions prior to 15.1R7. |
| Dolibarr ERP/CRM is affected by multiple reflected Cross-Site Scripting (XSS) vulnerabilities in versions before 5.0.4: index.php (leftmenu parameter), core/ajax/box.php (PATH_INFO), product/stats/card.php (type parameter), holiday/list.php (month_create, month_start, and month_end parameters), and don/card.php (societe, lastname, firstname, address, zipcode, town, and email parameters). |
| The National Payments Corporation of India BHIM application 1.3 for Android relies on three hardcoded strings (AK-NPCIMB, IM-NPCIBM, and VK-NPCIBM) for SMS validation, which makes it easier for attackers to bypass authentication. |
| OX Software GmbH OX App Suite 7.8.4 and earlier is affected by: Cross Site Scripting (XSS). |
| Cross-site scripting (XSS) vulnerability in ProjectSend (formerly cFTP) before commit 6c3710430be26feb5371cb0377e5355d6f9a27ca allows remote attackers to inject arbitrary web script or HTML via the Description field in My account Name updated, related to home.php and actions-log.php. |
| Cross-site scripting (XSS) vulnerability in ProjectSend (formerly cFTP) before commit 6c3710430be26feb5371cb0377e5355d6f9a27ca allows remote attackers to inject arbitrary web script or HTML via the Description field in a Site name updated. |
| Certain 802.11 network management messages have been determined to invoke wireless access point blacklisting security defenses when not required, which can necessitate intervention by hospital staff to reset the device and reestablish a network connection to the Wi-Fi access point. During this state, the Philips IntelliVue MX40 Version B.06.18 can either connect to an alternative access point within signal range for association to a central monitoring station, or it can remain in local monitoring mode until the device is reset by hospital staff. CVSS v3 base score: 6.5, CVSS vector string: AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H. Philips has released software update, Version B.06.18, to fix the improper cleanup on thrown exception vulnerability, and implement mitigations to reduce the risk associated with the improper handling of exceptional conditions vulnerability. The software update implements messaging and alarming on the MX40 and at the central monitoring station, when the MX40 disconnects from the access point. |
| Under specific 802.11 network conditions, a partial re-association of the Philips IntelliVue MX40 Version B.06.18 WLAN monitor to the central monitoring station is possible. In this state, the central monitoring station can indicate the MX40 is not connected or associated to the central monitor, and thus should be operating in local monitoring mode (local audio-on, screen-on), but the MX40 WLAN itself can instead still be operating in telemetry mode (local audio-off, screen-off). If a patient experiences an alarm event and clinical staff expects the MX40 to provide local alarming when it is not available from the local device, a delay of treatment can occur. CVSS v3 base score: 6.5, CVSS vector string: AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H. Philips has released software update, Version B.06.18, to fix the improper cleanup on thrown exception vulnerability, and implement mitigations to reduce the risk associated with the improper handling of exceptional conditions vulnerability. The software update implements messaging and alarming on the MX40 and at the central monitoring station, when the MX40 disconnects from the access point. |
| The backend database of the Philips DoseWise Portal application versions 1.1.7.333 and 2.1.1.3069 uses hard-coded credentials for a database account with privileges that can affect confidentiality, integrity, and availability of the database. For an attacker to exploit this vulnerability, elevated privileges are first required for an attacker to access the web application backend system files that contain the hard-coded credentials. Successful exploitation may allow a remote attacker to gain access to the database of the DWP application, which contains PHI. CVSS v3 base score: 9.1, CVSS vector string: AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H. |
| Mitsubishi E-Designer, Version 7.52 Build 344 contains two code sections which may be exploited to allow an attacker to overwrite arbitrary memory locations. This can result in arbitrary code execution, compromised data integrity, denial of service, and system crash. |