Export limit exceeded: 370356 CVEs match your query. Please refine your search to export 10,000 CVEs or fewer.
Search
Search Results (1112 CVEs found)
| CVE | Vendors | Products | Updated | CVSS v3.1 |
|---|---|---|---|---|
| CVE-2025-20155 | 1 Cisco | 1 Ios Xe | 2026-02-26 | 6 Medium |
| A vulnerability in the bootstrap loading of Cisco IOS XE Software could allow an authenticated, local attacker to write arbitrary files to an affected system. This vulnerability is due to insufficient input validation of the bootstrap file that is read by the system software when a device is first deployed in SD-WAN mode or when an administrator configures SD-Routing on the device. An attacker could exploit this vulnerability by modifying a bootstrap file generated by Cisco Catalyst SD-WAN Manager, loading it into the device flash, and then either reloading the device in a green field deployment in SD-WAN mode or configuring the device with SD-Routing. A successful exploit could allow the attacker to perform arbitrary file writes to the underlying operating system. | ||||
| CVE-2025-43878 | 1 F5 | 13 F5os-a, F5os-c, R10600 and 10 more | 2026-02-26 | 6 Medium |
| When running in Appliance mode, an authenticated attacker assigned the Administrator or Resource Administrator role may be able to bypass Appliance mode restrictions utilizing system diagnostics tcpdump command utility on a F5OS-C/A system. Note: Software versions which have reached End of Technical Support (EoTS) are not evaluated. | ||||
| CVE-2025-3357 | 1 Ibm | 1 Tivoli Monitoring | 2026-02-26 | 9.8 Critical |
| IBM Tivoli Monitoring 6.3.0.7 through 6.3.0.7 Service Pack 19 could allow a remote attacker to execute arbitrary code due to improper validation of an index value of a dynamically allocated array. | ||||
| CVE-2025-5349 | 1 Citrix | 2 Netscaler Application Delivery Controller, Netscaler Gateway | 2026-02-26 | 8.8 High |
| Improper access control on the NetScaler Management Interface in NetScaler ADC and NetScaler Gateway | ||||
| CVE-2025-7848 | 1 Ni | 1 Labview | 2026-02-26 | 7.8 High |
| A memory corruption vulnerability due to improper input validation in lvpict.cpp exists in NI LabVIEW that may result in arbitrary code execution. Successful exploitation requires an attacker to get a user to open a specially crafted VI. This vulnerability affects NI LabVIEW 2025 Q1 and prior versions. | ||||
| CVE-2025-7849 | 1 Ni | 1 Labview | 2026-02-26 | 7.8 High |
| A memory corruption vulnerability due to improper error handling when a VILinkObj is null exists in NI LabVIEW that may result in arbitrary code execution. Successful exploitation requires an attacker to get a user to open a specially crafted VI. This vulnerability affects NI LabVIEW 2025 Q1 and prior versions. | ||||
| CVE-2025-30027 | 1 Axis | 1 Axis Os | 2026-02-26 | 6.7 Medium |
| An ACAP configuration file lacked sufficient input validation, which could allow for arbitrary code execution. This vulnerability can only be exploited if the Axis device is configured to allow the installation of unsigned ACAP applications, and if an attacker convinces the victim to install a malicious ACAP application. | ||||
| CVE-2025-55701 | 1 Microsoft | 30 Windows, Windows 10, Windows 10 1507 and 27 more | 2026-02-26 | 7.8 High |
| Improper validation of specified type of input in Microsoft Windows allows an authorized attacker to elevate privileges locally. | ||||
| CVE-2025-4645 | 2 Axis, Axis Communications Ab | 234 A1210 \(-b\), A1214, A1601 and 231 more | 2026-02-26 | 6.7 Medium |
| An ACAP configuration file lacked sufficient input validation, which could allow for arbitrary code execution. This vulnerability can only be exploited if the Axis device is configured to allow the installation of unsigned ACAP applications, and if an attacker convinces the victim to install a malicious ACAP application. | ||||
| CVE-2025-6298 | 2 Axis, Axis Communications Ab | 2 Axis Os, Axis Os | 2026-02-26 | 6.7 Medium |
| ACAP applications can gain elevated privileges due to improper input validation, potentially leading to privilege escalation. This vulnerability can only be exploited if the Axis device is configured to allow the installation of unsigned ACAP applications, and if an attacker convinces the victim to install a malicious ACAP application. | ||||
| CVE-2025-8108 | 2 Axis, Axis Communications Ab | 234 A1210 \(-b\), A1214, A1601 and 231 more | 2026-02-26 | 6.7 Medium |
| An ACAP configuration file has improper permissions and lacks input validation, which could potentially lead to privilege escalation. This vulnerability can only be exploited if the Axis device is configured to allow the installation of unsigned ACAP applications, and if an attacker convinces the victim to install a malicious ACAP application. | ||||
| CVE-2025-61938 | 1 F5 | 3 Big-ip, Big-ip Advanced Web Application Firewall, Big-ip Application Security Manager | 2026-02-26 | 7.5 High |
| When a BIG-IP Advanced WAF or ASM security policy is configured with a URL greater than 1024 characters in length for the Data Guard Protection Enforcement setting, either manually or through the automatic Policy Builder, the bd process can terminate repeatedly. Note: Software versions which have reached End of Technical Support (EoTS) are not evaluated. | ||||
| CVE-2025-36094 | 1 Ibm | 1 Cloud Pak For Business Automation | 2026-02-25 | 5.4 Medium |
| IBM Cloud Pak for Business Automation 25.0.0 through 25.0.0 Interim Fix 002, 24.0.1 through 24.0.1 Interim Fix 005, and 24.0.0 through 24.0.0 Interim Fix 007 could allow an authenticated user to cause a denial of service or corrupt existing data due to the improper validation of input length. | ||||
| CVE-2022-2845 | 2 Fedoraproject, Vim | 2 Fedora, Vim | 2026-02-25 | 7.8 High |
| Improper Validation of Specified Quantity in Input in GitHub repository vim/vim prior to 9.0.0218. | ||||
| CVE-2020-16220 | 1 Philips | 2 Patient Information Center Ix, Performancebridge Focal Point | 2026-02-23 | 4.3 Medium |
| In Patient Information Center iX (PICiX) Versions C.02, C.03, PerformanceBridge Focal Point Version A.01, the product receives input that is expected to be well-formed (i.e., to comply with a certain syntax) but it does not validate or incorrectly validates that the input complies with the syntax, causing the certificate enrollment service to crash. It does not impact monitoring but prevents new devices from enrolling. | ||||
| CVE-2025-59278 | 1 Microsoft | 28 Windows, Windows 10, Windows 10 1507 and 25 more | 2026-02-22 | 7.8 High |
| Improper validation of specified type of input in Windows Authentication Methods allows an authorized attacker to elevate privileges locally. | ||||
| CVE-2025-59275 | 1 Microsoft | 28 Windows, Windows 10, Windows 10 1507 and 25 more | 2026-02-22 | 7.8 High |
| Improper validation of specified type of input in Windows Authentication Methods allows an authorized attacker to elevate privileges locally. | ||||
| CVE-2025-58729 | 1 Microsoft | 31 Windows, Windows 10, Windows 10 1507 and 28 more | 2026-02-22 | 6.5 Medium |
| Improper validation of specified type of input in Windows Local Session Manager (LSM) allows an authorized attacker to deny service over a network. | ||||
| CVE-2025-59277 | 1 Microsoft | 28 Windows, Windows 10, Windows 10 1507 and 25 more | 2026-02-22 | 7.8 High |
| Improper validation of specified type of input in Windows Authentication Methods allows an authorized attacker to elevate privileges locally. | ||||
| CVE-2025-59259 | 1 Microsoft | 27 Windows, Windows 10, Windows 10 1507 and 24 more | 2026-02-22 | 6.5 Medium |
| Improper validation of specified type of input in Windows Local Session Manager (LSM) allows an authorized attacker to deny service over a network. | ||||