CVE-2020-29062 1 Cdatatec 56 72408a, 72408a Firmware, 9008a and 53 more 2024-11-21 9.8 Critical
An issue was discovered on CDATA 72408A, 9008A, 9016A, 92408A, 92416A, 9288, 97016, 97024P, 97028P, 97042P, 97084P, 97168P, FD1002S, FD1104, FD1104B, FD1104S, FD1104SN, FD1108S, FD1204S-R2, FD1204SN, FD1204SN-R2, FD1208S-R2, FD1216S-R1, FD1608GS, FD1608SN, FD1616GS, FD1616SN, and FD8000 devices. There is a default blank password for the guest account.
CVE-2020-29061 1 Cdatatec 56 72408a, 72408a Firmware, 9008a and 53 more 2024-11-21 9.8 Critical
An issue was discovered on CDATA 72408A, 9008A, 9016A, 92408A, 92416A, 9288, 97016, 97024P, 97028P, 97042P, 97084P, 97168P, FD1002S, FD1104, FD1104B, FD1104S, FD1104SN, FD1108S, FD1204S-R2, FD1204SN, FD1204SN-R2, FD1208S-R2, FD1216S-R1, FD1608GS, FD1608SN, FD1616GS, FD1616SN, and FD8000 devices. There is a default root126 password for the root account.
CVE-2020-29060 1 Cdatatec 56 72408a, 72408a Firmware, 9008a and 53 more 2024-11-21 9.8 Critical
An issue was discovered on CDATA 72408A, 9008A, 9016A, 92408A, 92416A, 9288, 97016, 97024P, 97028P, 97042P, 97084P, 97168P, FD1002S, FD1104, FD1104B, FD1104S, FD1104SN, FD1108S, FD1204S-R2, FD1204SN, FD1204SN-R2, FD1208S-R2, FD1216S-R1, FD1608GS, FD1608SN, FD1616GS, FD1616SN, and FD8000 devices. There is a default debug124 password for the debug account.
CVE-2020-29059 1 Cdatatec 56 72408a, 72408a Firmware, 9008a and 53 more 2024-11-21 9.8 Critical
An issue was discovered on CDATA 72408A, 9008A, 9016A, 92408A, 92416A, 9288, 97016, 97024P, 97028P, 97042P, 97084P, 97168P, FD1002S, FD1104, FD1104B, FD1104S, FD1104SN, FD1108S, FD1204S-R2, FD1204SN, FD1204SN-R2, FD1208S-R2, FD1216S-R1, FD1608GS, FD1608SN, FD1616GS, FD1616SN, and FD8000 devices. There is a default panger123 password for the suma123 account for certain old firmware.
CVE-2020-29056 2 Cdata, Cdatatec 57 Fd1104 Firmware, 72408a, 72408a Firmware and 54 more 2024-11-21 9.8 Critical
An issue was discovered on CDATA 72408A, 9008A, 9016A, 92408A, 92416A, 9288, 97016, 97024P, 97028P, 97042P, 97084P, 97168P, FD1002S, FD1104, FD1104B, FD1104S, FD1104SN, FD1108S, FD1204S-R2, FD1204SN, FD1204SN-R2, FD1208S-R2, FD1216S-R1, FD1608GS, FD1608SN, FD1616GS, FD1616SN, and FD8000 devices. One can escape from a shell and acquire root privileges by leveraging the TFTP download configuration.
CVE-2020-29053 1 Hrsale 1 Hrsale 2024-11-21 6.1 Medium
HRSALE 2.0.0 allows XSS via the admin/project/projects_calendar set_date parameter.
CVE-2020-29040 1 Xen 1 Xen 2024-11-21 8.8 High
An issue was discovered in Xen through 4.14.x allowing x86 HVM guest OS users to cause a denial of service (stack corruption), cause a data leak, or possibly gain privileges because of an off-by-one error. NOTE: this issue is caused by an incorrect fix for CVE-2020-27671.
CVE-2020-29029 1 Secomea 1 Gatemanager Firmware 2024-11-21 7.3 High
Improper Input Validation, Cross-site Scripting (XSS) vulnerability in Web GUI of Secomea GateManager allows an attacker to execute arbitrary javascript code. This issue affects: Secomea GateManager all versions prior to 9.4.
CVE-2020-29028 1 Secomea 1 Gatemanager Firmware 2024-11-21 6.3 Medium
Cross-site Scripting (XSS) vulnerability in web GUI of Secomea GateManager allows an attacker to inject arbitrary javascript code. This issue affects: Secomea GateManager all versions prior to 9.4.
CVE-2020-29027 1 Secomea 18 Sitemanager 1129, Sitemanager 1129 Firmware, Sitemanager 1139 and 15 more 2024-11-21 5.4 Medium
Cross-site Scripting (XSS) vulnerability in GUI of Secomea SiteManager could allow an attacker to cause an XSS Attack. This issue affects: Secomea SiteManager all versions prior to 9.3.
CVE-2020-29025 1 Secomea 1 Sitemanager Embedded 2024-11-21 5.4 Medium
A vulnerability in SiteManager-Embedded (SM-E) Web server which may allow attacker to construct a URL that if visited by another application user, will cause JavaScript code supplied by the attacker to execute within the user's browser in the context of that user's session with the application. This issue affects all versions and variants of SM-E prior to version 9.3
CVE-2020-29021 1 Secomea 8 Gatemanager 4250, Gatemanager 4250 Firmware, Gatemanager 4260 and 5 more 2024-11-21 3.5 Low
A vulnerability in web UI input field of GateManager allows authenticated attacker to enter script tags that could cause XSS. This issue affects: GateManager all versions prior to 9.3.
CVE-2020-29019 1 Fortinet 1 Fortiweb 2024-11-21 5.3 Medium
A stack-based buffer overflow vulnerability in FortiWeb 6.3.0 through 6.3.7 and version before 6.2.4 may allow a remote, unauthenticated attacker to crash the httpd daemon thread by sending a request with a crafted cookie header.
CVE-2020-29017 1 Fortinet 1 Fortideceptor 2024-11-21 8.8 High
An OS command injection vulnerability in FortiDeceptor 3.1.0, 3.0.1, 3.0.0 may allow a remote authenticated attacker to execute arbitrary commands on the system by exploiting a command injection vulnerability on the Customization page.
CVE-2020-29016 1 Fortinet 1 Fortiweb 2024-11-21 9.8 Critical
A stack-based buffer overflow vulnerability in FortiWeb 6.3.0 through 6.3.5 and version before 6.2.4 may allow an unauthenticated, remote attacker to overwrite the content of the stack and potentially execute arbitrary code by sending a crafted request with a large certname.
CVE-2020-29003 1 Mediawiki 1 Mediawiki 2024-11-21 5.4 Medium
The PollNY extension for MediaWiki through 1.35 allows XSS via an answer option for a poll question, entered during Special:CreatePoll or Special:UpdatePoll.
CVE-2020-29002 1 Mediawiki 1 Mediawiki 2024-11-21 4.8 Medium
includes/CologneBlueTemplate.php in the CologneBlue skin for MediaWiki through 1.35 allows XSS via a qbfind message supplied by an administrator.
CVE-2020-28999 1 Mygeeni 2 Gnc-cw013, Gnc-cw013 Firmware 2024-11-21 7.2 High
An issue was discovered in Apexis Streaming Video Web Application on Geeni GNC-CW013 doorbell 1.8.1 devices. A remote attacker can take full control of the camera with a high-privileged account. The vulnerability exists because a static username and password are compiled into a shared library (libhipcam.so) used to provide the streaming camera service.
CVE-2020-28998 1 Mygeeni 2 Gnc-cw013, Gnc-cw013 Firmware 2024-11-21 9.8 Critical
An issue was discovered on Geeni GNC-CW013 doorbell 1.8.1 devices. A vulnerability exists in the Telnet service that allows a remote attacker to take full control of the device with a high-privileged account. The vulnerability exists because a system account has a default and static password.
CVE-2020-28968 1 Draytek 26 Vigorap 1000c, Vigorap 1000c Firmware, Vigorap 700 and 23 more 2024-11-21 5.4 Medium
Draytek VigorAP 1000C contains a stored cross-site scripting (XSS) vulnerability in the RADIUS Setting - RADIUS Server Configuration module. This vulnerability allows attackers to execute arbitrary web scripts or HTML via a crafted payload in the username input field.