Search Results (401 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2009-0472 1 Rockwellautomation 1 Controllogix 1756-enbt\/a Ethernet\/ Ip Bridge 2026-04-23 N/A
Multiple cross-site scripting (XSS) vulnerabilities in the web interface in the Rockwell Automation ControlLogix 1756-ENBT/A EtherNet/IP Bridge Module allow remote attackers to inject arbitrary web script or HTML via unspecified vectors.
CVE-2009-3739 1 Rockwellautomation 2 Ab Micrologix Controller 1100, Ab Micrologix Controller 1400 2026-04-23 N/A
Multiple unspecified vulnerabilities on the Rockwell Automation AB Micrologix 1100 and 1400 controllers allow remote attackers to obtain privileged access or cause a denial of service (halt) via unknown vectors.
CVE-2009-0474 1 Rockwellautomation 1 Controllogix 1756-enbt\/a Ethernet\/ Ip Bridge 2026-04-23 N/A
The web interface in the Rockwell Automation ControlLogix 1756-ENBT/A EtherNet/IP Bridge Module allows remote attackers to obtain "internal web page information" and "internal information about the module" via unspecified vectors. NOTE: this may overlap CVE-2002-1603.
CVE-2009-0473 1 Rockwellautomation 1 Controllogix 1756-enbt\/a Ethernet\/ Ip Bridge 2026-04-23 N/A
Open redirect vulnerability in the web interface in the Rockwell Automation ControlLogix 1756-ENBT/A EtherNet/IP Bridge Module allows remote attackers to redirect users to arbitrary web sites and conduct phishing attacks via unspecified vectors.
CVE-2025-11085 1 Rockwellautomation 1 Factorytalk 2026-04-15 N/A
A security issue exists within DataMosaix™ Private Cloud allowing for Persistent XSS. This vulnerability can result in the execution of malicious JavaScript, allowing for account takeover, credential theft, or redirection to a malicious website.
CVE-2019-25276 1 Rockwellautomation 2 Factorytalk Activation, Studio 2026-04-15 7.8 High
Studio 5000 Logix Designer 30.01.00 contains an unquoted service path vulnerability in the FactoryTalk Activation Service that allows local users to potentially execute code with elevated privileges. Attackers can exploit the unquoted path in C:\Program Files (x86)\Rockwell Software\FactoryTalk Activation\ to inject malicious code that would execute with LocalSystem permissions.
CVE-2025-11862 1 Rockwellautomation 1 Verve Asset Manager 2026-04-15 N/A
A security issue was discovered within Verve Asset Manager allowing unauthorized read-only users to read, update, and delete users via the API.
CVE-2025-7973 1 Rockwellautomation 1 Factorytalk View 2026-04-15 N/A
A security issue exists in FactoryTalk ViewPoint version 14.0 or below due to improper handling of MSI repair operations. During a repair, attackers can hijack the cscript.exe console window, which runs with SYSTEM privileges. This can be exploited to spawn an elevated command prompt, enabling full privilege escalation.
CVE-2025-9437 1 Rockwellautomation 1 Armorstart Aop 2026-04-15 N/A
A security issue exists within the Studio 5000 Logix Designer add-on profile (AOP) for the ArmorStart Classic distributed motor controller, resulting in denial-of-service. This vulnerability is possible due to the input of invalid values into Component Object Model (COM) methods.
CVE-2024-6078 1 Rockwellautomation 1 Datamosaix 2026-04-15 N/A
CVE-2024-6078 IMPACT An improper authentication vulnerability exists in the affected product, which could allow a malicious user to generate cookies for any user ID without the use of a username or password. If exploited, a malicious user could take over the account of a legitimate user. The malicious user would be able to view and modify data stored in the cloud.
CVE-2025-7774 1 Rockwellautomation 1 Armorblock 5000 Io 2026-04-15 N/A
A security issue exists within the 5032 16pt Digital Configurable module’s web server. Intercepted session credentials can be used within a 3-minute timeout window, allowing unauthorized users to perform privileged actions.
CVE-2025-7773 1 Rockwellautomation 1 Armorblock 5000 Io 2026-04-15 N/A
A security issue exists within the 5032 16pt Digital Configurable module’s web server. The web server’s session number increments at an interval that correlates to the last two consecutive sign in session interval, making it predictable.
CVE-2025-9177 1 Rockwellautomation 1 1715-aentr Ethernet/ip Adapter 2026-04-15 N/A
A denial-of-service security issue exists in the affected product and version. The security issue stems from a high number of requests sent to the web server. This could result in a web server crash however; this does not impact I/O control or communication . A power cycle is required to recover and utilize the webpage.
CVE-2025-9178 1 Rockwellautomation 1 1715-aentr Eternet/ip Adapter 2026-04-15 N/A
A denial-of-service security issue exists in the affected product and version. The security issue is caused through CIP communication using crafted payloads. The security issue could result in no CIP communication with 1715 EtherNet/IP Adapter.A restart is required to recover.
CVE-2025-9066 1 Rockwellautomation 1 Factorytalk View 2026-04-15 N/A
A security issue was discovered within FactoryTalk® ViewPoint, allowing unauthenticated attackers to achieve XXE. Certain SOAP requests can be abused to perform XXE, resulting in a temporary denial-of-service.
CVE-2025-7353 1 Rockwellautomation 1 Controllogix 2026-04-15 N/A
A security issue exists due to the web-based debugger agent enabled on Rockwell Automation ControlLogix® Ethernet Modules. If a specific IP address is used to connect to the WDB agent, it can allow remote attackers to perform memory dumps, modify memory, and control execution flow.
CVE-2025-9368 1 Rockwellautomation 1 432es-ig3 Series A 2026-04-15 N/A
A security issue exists within 432ES-IG3 Series A, which affects GuardLink® EtherNet/IP Interface, resulting in denial-of-service. A manual power cycle is required to recover the device.
CVE-2025-7971 1 Rockwellautomation 1 Studio 5000 Logix Designer 2026-04-15 N/A
A security issues exists within Studio 5000 Logix Designer due to unsafe handling of environment variables. If the specified path lacks a valid file, Logix Designer crashes; However, it may be possible to execute malicious code without triggering a crash.
CVE-2024-10943 1 Rockwellautomation 1 Factorytalk Updater 2026-04-15 9.1 Critical
An authentication bypass vulnerability exists in the affected product. The vulnerability exists due to shared secrets across accounts and could allow a threat actor to impersonate a user if the threat actor is able to enumerate additional information required during authentication.
CVE-2024-7567 1 Rockwellautomation 2 Micro850 Firmware, Micro870 Firmware 2026-04-15 N/A
A denial-of-service vulnerability exists via the CIP/Modbus port in the Rockwell Automation Micro850/870 (2080 -L50E/2080 -L70E). If exploited, the CIP/Modbus communication may be disrupted for short duration.