Export limit exceeded: 48179 CVEs match your query. Please refine your search to export 10,000 CVEs or fewer.
Search
Search Results (62 CVEs found)
| CVE | Vendors | Products | Updated | CVSS v3.1 |
|---|---|---|---|---|
| CVE-2025-55069 | 1 Automationdirect | 1 Click Plus | 2026-04-15 | 8.3 High |
| A predictable seed in pseudo-random number generator vulnerability has been discovered in firmware version 3.60 of the Click Plus PLC. The vulnerability relies on the fact that the software implements a predictable seed for its pseudo-random number generator, which compromises the security of the generated private keys. | ||||
| CVE-2025-57882 | 1 Automationdirect | 1 Click Plus | 2026-04-15 | 5.9 Medium |
| An improper resource shutdown or release vulnerability has been identified in the Click Plus C2-03CPU-2 device running firmware version 3.60. The vulnerability allows an unauthenticated attacker to perform a denial-of-service attack by exhausting all available device sessions in the Remote PLC application. | ||||
| CVE-2025-36535 | 1 Automationdirect | 1 Mb Gateway | 2026-04-15 | 10 Critical |
| The embedded web server lacks authentication and access controls, allowing unrestricted remote access. This could lead to configuration changes, operational disruption, or arbitrary code execution depending on the environment and exposed functionality. | ||||
| CVE-2024-43099 | 1 Automationdirect | 1 H2-dm1e Firmware | 2026-04-15 | 8.8 High |
| The session hijacking attack targets the application layer's control mechanism, which manages authenticated sessions between a host PC and a PLC. During such sessions, a session key is utilized to maintain security. However, if an attacker captures this session key, they can inject traffic into an ongoing authenticated session. To successfully achieve this, the attacker also needs to spoof both the IP address and MAC address of the originating host which is typical of a session-based attack. | ||||
| CVE-2024-45368 | 1 Automationdirect | 1 H2-dm1e Firmware | 2026-04-15 | 8.8 High |
| The H2-DM1E PLC's authentication protocol appears to utilize either a custom encoding scheme or a challenge-response protocol. However, there's an observed anomaly in the H2-DM1E PLC's protocol execution, namely its acceptance of multiple distinct packets as valid authentication responses. This behavior deviates from standard security practices where a single, specific response or encoding pattern is expected for successful authentication. | ||||
| CVE-2025-54855 | 1 Automationdirect | 1 Click Plus | 2026-04-15 | 4.2 Medium |
| Cleartext storage of sensitive information was discovered in Click Programming Software version v3.60. The vulnerability can be exploited by a local user with access to the file system, while an administrator session is active, to steal credentials stored in clear text. | ||||
| CVE-2025-67652 | 1 Automationdirect | 1 Click Plc | 2026-04-15 | 6.1 Medium |
| An attacker with access to the project file could use the exposed credentials to impersonate users, escalate privileges, or gain unauthorized access to systems and services. The absence of robust encryption or secure handling mechanisms increases the likelihood of this type of exploitation, leaving sensitive information more vulnerable. | ||||
| CVE-2024-11611 | 1 Automationdirect | 18 C-more Ea9-rhmi, C-more Ea9-rhmi Firmware, C-more Ea9-t10cl and 15 more | 2025-08-12 | N/A |
| AutomationDirect C-More EA9 EAP9 File Parsing Memory Corruption Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of AutomationDirect C-More EA9. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the parsing of EAP9 files. The issue results from the lack of proper validation of user-supplied data, which can result in a memory corruption condition. An attacker can leverage this vulnerability to execute code in the context of the current process. Was ZDI-CAN-24774. | ||||
| CVE-2024-11610 | 1 Automationdirect | 18 C-more Ea9-rhmi, C-more Ea9-rhmi Firmware, C-more Ea9-t10cl and 15 more | 2025-08-12 | N/A |
| AutomationDirect C-More EA9 EAP9 File Parsing Memory Corruption Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of AutomationDirect C-More EA9. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the parsing of EAP9 files. The issue results from the lack of proper validation of user-supplied data, which can result in a memory corruption condition. An attacker can leverage this vulnerability to execute code in the context of the current process. Was ZDI-CAN-24773. | ||||
| CVE-2024-11609 | 1 Automationdirect | 18 C-more Ea9-rhmi, C-more Ea9-rhmi Firmware, C-more Ea9-t10cl and 15 more | 2025-08-12 | N/A |
| AutomationDirect C-More EA9 EAP9 File Parsing Stack-based Buffer Overflow Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of AutomationDirect C-More EA9. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the parsing of EAP9 files. The issue results from the lack of proper validation of the length of user-supplied data prior to copying it to a fixed-length stack-based buffer. An attacker can leverage this vulnerability to execute code in the context of the current process. Was ZDI-CAN-24772. | ||||
| CVE-2017-14020 | 1 Automationdirect | 10 C-more Micro, C-more Micro Firmware, C-more Plc and 7 more | 2025-04-20 | N/A |
| In AutomationDirect CLICK Programming Software (Part Number C0-PGMSW) Versions 2.10 and prior; C-More Programming Software (Part Number EA9-PGMSW) Versions 6.30 and prior; C-More Micro (Part Number EA-PGMSW) Versions 4.20.01.0 and prior; Do-more Designer Software (Part Number DM-PGMSW) Versions 2.0.3 and prior; GS Drives Configuration Software (Part Number GSOFT) Versions 4.0.6 and prior; SL-SOFT SOLO Temperature Controller Configuration Software (Part Number SL-SOFT) Versions 1.1.0.5 and prior; and DirectSOFT Programming Software Versions 6.1 and prior, an uncontrolled search path element (DLL Hijacking) vulnerability has been identified. To exploit this vulnerability, an attacker could rename a malicious DLL to meet the criteria of the application, and the application would not verify that the DLL is correct. Once loaded by the application, the DLL could run malicious code at the privilege level of the application. | ||||
| CVE-2022-2006 | 1 Automationdirect | 24 C-more Ea9-pgmsw, C-more Ea9-pgmsw Firmware, C-more Ea9-rhmi and 21 more | 2025-04-16 | 7.8 High |
| AutomationDirect DirectLOGIC has a DLL vulnerability in the install directory that may allow an attacker to execute code during the installation process. This issue affects: AutomationDirect C-more EA9 EA9-T6CL versions prior to 6.73; EA9-T6CL-R versions prior to 6.73; EA9-T7CL versions prior to 6.73; EA9-T7CL-R versions prior to 6.73; EA9-T8CL versions prior to 6.73; EA9-T10CL versions prior to 6.73; EA9-T10WCL versions prior to 6.73; EA9-T12CL versions prior to 6.73; EA9-T15CL versions prior to 6.73; EA9-RHMI versions prior to 6.73; EA9-PGMSW versions prior to 6.73; | ||||
| CVE-2022-2003 | 1 Automationdirect | 18 D0-06aa, D0-06aa Firmware, D0-06ar and 15 more | 2025-04-16 | 7.7 High |
| AutomationDirect DirectLOGIC is vulnerable to a specifically crafted serial message to the CPU serial port that will cause the PLC to respond with the PLC password in cleartext. This could allow an attacker to access and make unauthorized changes. This issue affects: AutomationDirect DirectLOGIC D0-06 series CPUs D0-06DD1 versions prior to 2.72; D0-06DD2 versions prior to 2.72; D0-06DR versions prior to 2.72; D0-06DA versions prior to 2.72; D0-06AR versions prior to 2.72; D0-06AA versions prior to 2.72; D0-06DD1-D versions prior to 2.72; D0-06DD2-D versions prior to 2.72; D0-06DR-D versions prior to 2.72; | ||||
| CVE-2022-2485 | 1 Automationdirect | 20 Sio-mb04ads, Sio-mb04ads Firmware, Sio-mb04das and 17 more | 2025-04-16 | 9.6 Critical |
| Any attempt (good or bad) to log into AutomationDirect Stride Field I/O with a web browser may result in the device responding with its password in the communication packets. | ||||
| CVE-2021-32980 | 1 Automationdirect | 40 C0-10are-d, C0-10are-d Firmware, C0-10dd1e-d and 37 more | 2025-04-16 | 9.8 Critical |
| Automation Direct CLICK PLC CPU Modules: C0-1x CPUs with firmware prior to v3.00 does not protect against additional software programming connections. An attacker can connect to the PLC while an existing connection is already active. | ||||
| CVE-2021-32978 | 1 Automationdirect | 40 C0-10are-d, C0-10are-d Firmware, C0-10dd1e-d and 37 more | 2025-04-16 | 7.5 High |
| The programming protocol allows for a previously entered password and lock state to be read by an attacker. If the previously entered password was successful, the attacker can then use the password to unlock Automation Direct CLICK PLC CPU Modules: C0-1x CPUs with firmware prior to v3.00. | ||||
| CVE-2021-32984 | 1 Automationdirect | 40 C0-10are-d, C0-10are-d Firmware, C0-10dd1e-d and 37 more | 2025-04-16 | 9.8 Critical |
| All programming connections receive the same unlocked privileges, which can result in a privilege escalation. During the time Automation Direct CLICK PLC CPU Modules: C0-1x CPUs with firmware prior to v3.00 is unlocked by an authorized user, an attacker can connect to the PLC and read the project without authorization. | ||||
| CVE-2021-32986 | 1 Automationdirect | 40 C0-10are-d, C0-10are-d Firmware, C0-10dd1e-d and 37 more | 2025-04-16 | 9.8 Critical |
| After Automation Direct CLICK PLC CPU Modules: C0-1x CPUs with firmware prior to v3.00 is unlocked by an authorized user, the unlocked state does not timeout. If the programming software is interrupted, the PLC remains unlocked. All subsequent programming connections are allowed without authorization. The PLC is only relocked by a power cycle, or when the programming software disconnects correctly. | ||||
| CVE-2021-32982 | 1 Automationdirect | 40 C0-10are-d, C0-10are-d Firmware, C0-10dd1e-d and 37 more | 2025-04-16 | 7.5 High |
| Automation Direct CLICK PLC CPU Modules: C0-1x CPUs with firmware prior to v3.00 passwords are sent as plaintext during unlocking and project transfers. An attacker who has network visibility can observe the password exchange. | ||||
| CVE-2022-2005 | 1 Automationdirect | 24 C-more Ea9-pgmsw, C-more Ea9-pgmsw Firmware, C-more Ea9-rhmi and 21 more | 2025-04-16 | 7.5 High |
| AutomationDirect C-more EA9 HTTP webserver uses an insecure mechanism to transport credentials from client to web server, which may allow an attacker to obtain the login credentials and login as a valid user. This issue affects: AutomationDirect C-more EA9 EA9-T6CL versions prior to 6.73; EA9-T6CL-R versions prior to 6.73; EA9-T7CL versions prior to 6.73; EA9-T7CL-R versions prior to 6.73; EA9-T8CL versions prior to 6.73; EA9-T10CL versions prior to 6.73; EA9-T10WCL versions prior to 6.73; EA9-T12CL versions prior to 6.73; EA9-T15CL versions prior to 6.73; EA9-RHMI versions prior to 6.73; EA9-PGMSW versions prior to 6.73; | ||||