Search Results (3428 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2024-48919 1 Cursor 1 Cursor 2026-04-15 N/A
Cursor is a code editor built for programming with AI. Prior to Sep 27, 2024, if a user generated a terminal command via Cursor's Terminal Cmd-K/Ctrl-K feature and if the user explicitly imported a malicious web page into the Terminal Cmd-K prompt, an attacker with control over the referenced web page could have a significant chance of influencing a language model to output arbitrary commands for execution in the user's terminal. This scenario would require the user explicitly opt-in to including the contents of a compromised webpage, and it would require that the attacker display prompt injection text in the the contents of the compromised webpage. A server-side patch to not stream back newlines or control characters was released on September 27, 2024, within two hours of the issue being reported. Additionally, Cursor 0.42 includes client-side mitigations to prevent any newline or control character from being streamed into the terminal directly. It also contains a new setting, `"cursor.terminal.usePreviewBox"`, which, if set to true, streams the response into a preview box whose contents then have to be manually accepted before being inserted into the terminal. This setting is useful if you're working in a shell environment where commands can be executed without pressing enter or any control character. The patch has been applied server-side, so no additional action is needed, even on older versions of Cursor. Separately, Cursor's maintainers also recommend, as best practice, to only include trusted pieces of context in prompts.
CVE-2024-49397 1 Elvaco 1 Cme3100 Firmware 2026-04-15 N/A
The affected product is vulnerable to a cross-site scripting attack which may allow an attacker to bypass authentication and takeover admin accounts.
CVE-2024-4995 2026-04-15 9.8 Critical
Wapro ERP Desktop is vulnerable to MS SQL protocol downgrade request from a server side, what could lead to an unencrypted communication vulnerable to data interception and modification. This issue affects Wapro ERP Desktop versions before 9.00.0.
CVE-2024-4996 2026-04-15 9.8 Critical
Use of a hard-coded password for a database administrator account created during Wapro ERP installation allows an attacker to retrieve embedded sensitive data stored in the database. The password is same among all Wapro ERP installations. This issue affects Wapro ERP Desktop versions before 8.90.0.
CVE-2024-47407 1 Myscada 2 Mypro Manager, Mypro Runtime 2026-04-15 10 Critical
A parameter within a command does not properly validate input within myPRO Manager which could be exploited by an unauthenticated remote attacker to inject arbitrary operating system commands.
CVE-2025-0674 2026-04-15 9.8 Critical
Multiple Elber products are affected by an authentication bypass vulnerability which allows unauthorized access to the password management functionality. Attackers can exploit this issue by manipulating the endpoint to overwrite any user's password within the system. This grants them unauthorized administrative access to protected areas of the application, compromising the device's system security.
CVE-2025-34143 2026-04-15 N/A
An authentication bypass vulnerability exists in ETQ Reliance on the CG (legacy) platform. The application allowed login as the privileged internal SYSTEM user by manipulating the username field. The SYSTEM account does not require a password, enabling attackers with network access to the login page to obtain elevated access. Once authenticated, an attacker could achieve remote code execution by modifying Jython scripts within the application. This issue was resolved by introducing stricter validation logic to exclude internal accounts from public authentication workflows in version MP-4583.
CVE-2024-45032 1 Siemens 2 Industrial Edge Management Pro, Industrial Edge Management Virtual 2026-04-15 10 Critical
A vulnerability has been identified in Industrial Edge Management Pro (All versions < V1.9.5), Industrial Edge Management Virtual (All versions < V2.3.1-1). Affected components do not properly validate the device tokens. This could allow an unauthenticated remote attacker to impersonate other devices onboarded to the system.
CVE-2024-45367 1 Optigo 1 Ons-s8 Firmware 2026-04-15 9.1 Critical
The web server for ONS-S8 - Spectra Aggregation Switch includes an incomplete authentication process, which can lead to an attacker authenticating without a password.
CVE-2024-45480 2026-04-15 N/A
An improper control of generation of code ('Code Injection') vulnerability in the AprolCreateReport component of B&R APROL <4.4-00P5 may allow an unauthenticated network-based attacker to read files from the local system.
CVE-2024-44087 1 Siemens 1 Automation License Manager 2026-04-15 8.6 High
A vulnerability has been identified in Automation License Manager V5 (All versions), Automation License Manager V6.0 (All versions < V6.0 SP12 Upd3), Automation License Manager V6.2 (All versions < V6.2 Upd3). Affected applications do not properly validate certain fields in incoming network packets on port 4410/tcp. This could allow an unauthenticated remote attacker to cause an integer overflow and crash of the application. This denial of service condition could prevent legitimate users from using subsequent products that rely on the affected application for license verification.
CVE-2025-3114 2026-04-15 N/A
Code Execution via Malicious Files: Attackers can create specially crafted files with embedded code that may execute without adequate security validation, potentially leading to system compromise. Sandbox Bypass Vulnerability: A flaw in the TERR security mechanism allows attackers to bypass sandbox restrictions, enabling the execution of untrusted code without appropriate controls.
CVE-2024-41988 1 Tem 1 Opera Plus Fm Family Transmitter 2026-04-15 N/A
TEM Opera Plus FM Family Transmitter allows access to an unprotected endpoint that allows MPFS File System binary image upload without authentication. This file system serves as the basis for the HTTP2 web server module but is also used by the SNMP module and is available to other applications that require basic read-only storage capabilities. This can be exploited to overwrite the flash program memory that holds the web server's main interfaces and execute arbitrary code.
CVE-2024-1244 2026-04-15 N/A
Improper input validation in the OSSEC HIDS agent for Windows prior to version 3.8.0 allows an attacker in with control over the OSSEC server or in possession of the agent's key to configure the agent to connect to a malicious UNC path. This results in the leakage of the machine account NetNTLMv2 hash, which can be relayed for remote code execution or used to escalate privileges to SYSTEM via AD CS certificate forging and other similar attacks.
CVE-2024-4332 1 Fortra 1 Tripwire Enterprise 2026-04-15 N/A
An authentication bypass vulnerability has been identified in the REST and SOAP API components of Tripwire Enterprise (TE) 9.1.0 when TE is configured to use LDAP/Active Directory SAML authentication and its optional "Auto-synchronize LDAP Users, Roles, and Groups" feature is enabled. This vulnerability allows unauthenticated attackers to bypass authentication if a valid username is known. Exploitation of this vulnerability could allow remote attackers to gain privileged access to the APIs and lead to unauthorized information disclosure or modification.
CVE-2024-43648 2026-04-15 8.8 High
Command injection in the <redacted> parameter of a <redacted>.exe request leads to remote code execution as the root user. This issue affects Iocharger firmware for AC models before version 24120701. Likelihood: Moderate – This action is not a common place for command injection vulnerabilities to occur. Thus, an attacker will likely only be able to find this vulnerability by reverse-engineering the firmware or trying it on all <redacted> fields. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a payload. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. CVSS clarification. The attack can be executed over any network connection the station is listening to and serves the web interface (AV:N), and there are no additional security measure sin place that need to be circumvented (AC:L), the attack does not rely on preconditions (AT:N). The attack does require authentication, but the level of authentication is irrelevant (PR:L), it does not require user interaction (UI:N). If is a full system compromise, potentially fully compromising confidentiality, integrity and availability of the devicer (VC:H/VI:H/VA:H).  A compromised charger can be used to "pivot" onto networks that should otherwise be closed, cause a low confidentiality and interity impact on subsequent systems. (SC:L/SI:L/SA:H). Because this device is an EV charger handing significant amounts of power, we suspect this vulnerability can have a safety impact (S:P). The attack can be automated (AU:Y).
CVE-2024-43652 2026-04-15 8.8 High
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root This issue affects Iocharger firmware for AC model chargers before version 24120701 Likelihood: Moderate – The <redacted> binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a crafted HTTP request. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services.
CVE-2024-43698 1 Kieback\&peter 10 Ddc4002 Firmware, Ddc4002e Firmware, Ddc4020e Firmware and 7 more 2026-04-15 9.8 Critical
Kieback & Peter's DDC4000 series uses weak credentials, which may allow an unauthenticated attacker to get full admin rights on the system.
CVE-2024-41925 1 Optigo 1 Ons-s8 Firmware 2026-04-15 9.8 Critical
The web service for ONS-S8 - Spectra Aggregation Switch includes functions which do not properly validate user input, allowing an attacker to traverse directories, bypass authentication, and execute remote code.
CVE-2023-5878 1 Honeywell 1 Onewireless Network Wireless Device Manager 2026-04-15 N/A
Honeywell OneWireless Wireless Device Manager (WDM) for the following versions R310.x, R320.x, R321.x, R322.1, R322.2, R323.x, R330.1 contains a command injection vulnerability. An attacker who is authenticated could use the firmware update process to potentially exploit the vulnerability, leading to a command injection. Honeywell recommends updating to R322.3, R330.2 or the most recent version of this product2.